12[Alarm] to set the alarm

The alarm page is used to set the alarm operation using the external I/O terminal of the camera, the alarm image, the area to detect the alarm, and the alarm notification. The Alarm page consists of the [Alarm], [VMD area], [SCD area], [Audio detection], and [Notification] tabs.
[Note:]

・The items that can be set differ depending on the function of the model.


・Refer to the catalog specifications for the functions installed in each model.


Click [Alarm] on the Alarm page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
This is used to set the operation when an alarm is detected. For the alarm image and output terminal settings, refer to the following.
12.4 [Alarm] to set alarm linkage operation
12.2 [Alarm] for setting the output terminal
Alarm
[Terminal 1]
Set the operation of terminal 1.
[Off]:Not used
[Alarm input (TRM1)]:The alarm input is received. When Alarm is selected, a pull-down menu ([Close], [Open], [Close(Continue)], [Open(Continue)]) is displayed.
[Close]:When the terminal status changes to [Close], an alarm is detected.
[Open]:When the terminal status changes to [Open], an alarm is detected.
[Close (Continue)]:When the terminal status changes to [Close], an alarm is detected. When the terminal status is [Close], the alarm is detected periodically at intervals of no alarm detection time.
[Open (continue)]:When the terminal status changes to [Open], an alarm is detected. When the terminal status is [Open], the alarm is detected periodically at intervals of no alarm detection time.
[Black and white switching input]:The black-and-white selector input is received. (When the input is [On], the input is switched to black and white)
[Automatic Time Adjustment]:Time setting by terminal input is accepted. When the signal is input, set to 00 minutes 00 seconds if the time difference from the normal time (00 minutes per hour) is 29 minutes or less. In the case of returning the time less than 5 seconds during SD recording, the time is not changed. Selecting Auto Time Adjustment displays the pull-down menu for short circuit and release selection.
[Close]:When the terminal status changes to [Close], the time is automatically adjusted.
[Open]:When the terminal status changes to [Open], the time is automatically adjusted.
[Terminal 2]
Set the operation of terminal 2.
[Off]:Not used
[Alarm input (TRM2)]:The alarm input is received. When Alarm is selected, a pull-down menu ([Close], [Open], [Close(Continue)], [Open(Continue)]) is displayed.
[Close]:When the terminal status changes to [Close], an alarm is detected.
[Open]:When the terminal status changes to [Open], an alarm is detected.
[Close (Continued)]:When the terminal status changes to [Close], an alarm is detected. When the terminal status is [Close], the alarm is detected periodically at intervals of no alarm detection time.
[Open (continued)]:When the terminal status changes to [Open], an alarm is detected. When the terminal status is [Open], the alarm is detected periodically at intervals of no alarm detection time.
[Alarm Output]:Alarm outputs according to the setting in [Output terminal].
12.2 [Alarm] for setting the output terminal
[Terminal 3]
Set the operation of terminal 3.
[Off]:Not used
[Alarm input (TRM3)]:The alarm input is received. When Alarm is selected, a pull-down menu ([Close], [Open], [Close(Continue)], [Open(Continue)]) is displayed.
[Close]:When the terminal status changes to [Close], an alarm is detected.
[Open]:When the terminal status changes to [Open], an alarm is detected.
[Close (Continued)]:When the terminal status changes to [Close], an alarm is detected. When the terminal status is [Close], the alarm is detected periodically at intervals of no alarm detection time.
[Open (continued)]:When the terminal status changes to [Open], an alarm is detected. When the terminal status is [Open], the alarm is detected periodically at intervals of no alarm detection time.
[Aux output]:AUX output is performed. The [AUX] buttons appear on the live picture pages.
[Important]

・It takes approximately 100 ms or longer to detect an alarm input to a short circuit (ON) or an alarm input to an open circuit (OFF) of the external I/O terminal. The alarm input will not be detected until the time set by [Alarm deactivation time] has elapsed.


[Note:]

・AUX is a camera terminal that can be operated (opened/closed) by the operator from the live image page. For example, when you want to operate lighting in the location where the camera is installed, you can operate it remotely by connecting it to a lighting control device.


・For the input/output ratings of each terminal, refer to the installation manual of the model.


[VMD alarm]
Clicking [VMD] displays the [VMD area] tabs on the Alarm Page.
12.6 [VMD area] to set the motion detection area

[Scene change detection (SCD) alarm]
Clicking [SCD] displays the [SCD area] tabs on the Alarm Page.
12.8 [SCD area] to set up undesired detection areas
[Auto track alarm]
Clicking [Auto track setting] displays the [Auto track alarm setting] tabs for the PTZ pages.
10.4 Set Auto Track Alarm (Auto Track Alarm screen)
[Audio detection alarm]
Clicking [Audio detection] displays the [Audio detection] tabs on the Alarm Page.
12.9 [Audio detection] for setting sound detection
[Command alarm]
Use [On] or [Off] to specify whether or not to accept the command alarm.
Command alarm is a function to receive unique alarm notification from other cameras. When set to [On], the alarms can be operated in conjunction with several cameras.
[Reception port]
Set the port number to which the command alarm is received.
Settable range:1~65535
The following port numbers cannot be set because they are used by this computer.
20、21、22、23、25、42、53、67、68、69、80、110、123、161、162、443、554、995、1883、8883、10669、10670、59000~61000
[Alarm deactivation time]
Sets the time when the alarm is detected and the detection operation is not executed. For example, this setting prevents sending too much mail to a mobile terminal or a tablet terminal when it is set to send mail notification by an alarm.

0.5s、1 ~ 600s


[Note:]

・Alarm detection time is managed for each alarm type. For example, the operation detection alarm and disturbance detection alarm are detected even during the no alarm detection time of the command alarm.


・[MULTI] The port numbers 32768 to 49151 cannot be set.


[Alarm test]
Clicking [Execute] performs the alarm test function.
[Note:]

・When the alarm test function is executed, the computer detects the command alarm.
This function can be used to record an SD Memory Card triggered by alarm detection or to confirm notification to an external device. Use the external device specified as the notification destination and the system log of this equipment to check the related settings.


・The alarm test function cannot be generated more than once within the alarm detection time.


Click [Alarm] on the Alarm page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
Here, the output terminal is set.
Output terminal

For the output terminal function, the [Terminal 2] of the [Alarm] setting must be set to [Alarm output].

[Terminal output upon alarm detection]
Sets on/off whether an alarm signal is output to the output terminal when an alarm is detected.

[SD memory card error]
The [On] or [Off] is used to determine whether to output signals to the output terminals when an SD memory card alarm is detected.
SD Memory Card Alarm Detection Conditions: SD Memory Card error (write error, read error, etc.), Operating time: 6 years, Overwrite count: 2,000 times
[On]:When the alarm condition is detected, a signal is output to the output terminal and [Alarm notification] of the live picture is popupped.
[Off]:Stops detecting the alarm condition.
[Important]

・To use this function correctly, format the SD Memory Card on your computer before using the SD Memory Card.


[Note:]

・Operation time: For 6 years, the power-on time after the SD card is inserted into the camera, and for 2000 times, the upper limit of the number of business SD Memory Card (MLC type) rewrites is used as a guide, and this does not guarantee a durability period.


・The output terminal and SD Memory Card Alarm use the same output terminal.


・When either an alarm or SD Memory Card alarm is activated, a signal is output to the output terminal.


・When an SD Memory Card Alarm is detected, the [Alarm Notice] on the live image page is popped out. Click the [x] button of [Alarm notification] to clear the [Alarm notification] display.


・The output signal output by the SD Memory Card alarm depends on the alarm format setting.
In the case of latches: The output signal continues for the duration of the cause of the SD Memory Card warning even after the alarm notification is cleared.
For pulses: The signal output of the output terminal continues while the cause of the SD Memory Card warning persists even after the alarm notification is cleared. However, when the time set in [Alarm output time] has elapsed, the signal output of the output terminal stops.


[Terminal state upon alarm detection]
Set the output terminal operation when an alarm is detected to either [Latch] or [Pulse].
[Latch]:When an alarm is detected, the alarm output terminal is set to [Terminal action upon alarm detection] until [x] is clicked in [Alarm notification].
[Pulse]:When an alarm is detected, the terminal at the time of alarm outputting is set by [Terminal action upon alarm detection] for the period set by [Pulse output width]. Click the [x] button of [Alarm notification] to return the output terminal to the normal state.

[Terminal action upon alarm detection]
Set the output status of the alarm output from the output terminal by [Open] or [Close].
[Open]:Set the alarm output terminal to Open (usually Close).
[Close]:The terminal at the time of alarm output is closed (normally open).
[Note:]

・When set to [Open], the alarm will be output for approximately 20 seconds when the power to the computer is turned on.


[Pulse output width]
Sets the time when the alarm is output from the output terminal when [Pulse] is selected in [Terminal state upon alarm detection].
Settable range:1~120s
Click [Alarm] on the Alarm page. (See the following for how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
You can change the [AUX], [Open], and [Close] names for live picture pages.
AUX title

[AUX (Up to 10 characters)]
Enter the [AUX] name for the live picture page.
Characters that cannot be entered:Half-pitch symbol " &

[Open (Up to 5 characters)]
Enter the [Open] name for the [AUX] buttons on the live picture pages.
Characters that cannot be entered:Half-pitch symbol " &

[Close (Up to 5 characters)]
Enter the [Close] name for the [AUX] buttons on the live picture pages.
Characters that cannot be entered:Half-pitch symbol " &
[Note:]

・The AUX name can be changed when [Terminal 3] in the [Alarm] setting is set to [AUX output].


・AUX is a camera terminal that can be operated (Open/Close) by the operator from the live picture page. For example, when you want to operate lighting in the location where the camera is installed, you can operate it remotely by connecting it to a lighting control device.


Click [Alarm] on the Alarm page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
This section sets the function to operate in conjunction with the alarm.
[Note:]

・Refer to the catalog specifications for the functions installed in each model.


・[PTZ] [Terminal alarm 1], [Terminal alarm 2], [Terminal alarm 3], [VMD alarm], [Scene change detection (SCD) alarm], [Audio detection alarm], and [Command alarm] can only be set for PTZ cameras.


[Terminal alarm 1]Select the action to be interlocked when terminal alarm 1 is detected from the following. This can be set when [Terminal 1] of the alarm is set to [Alarm input(TRM1)].
[Off]:Interlock operation is not performed even if terminal alarm 1 is detected.
1~256:When the preset position registered in advance is selected, the watch moves to the preset position when terminal alarm 1 is detected.
[Patrol 1]:When terminal alarm 1 is detected, patrol starts. *When Patrol 1 is not registered, it is not displayed.

[Terminal alarm 2]
Select the action to be interlocked when terminal alarm 2 is detected from the following. This can be set when [Terminal 2] of the alarm is set to [Alarm input(TRM2)].
[Off]:Interlock operation is not performed even if terminal alarm 2 is detected.
1~256:When the preset position registered in advance is selected, it moves to the position when terminal alarm 2 is detected.
[Patrol 2]:When terminal alarm 2 is detected, patrol starts. *When Patrol 2 is not registered, it is not displayed.
[Terminal alarm 3]
Select the action to interlock when terminal alarm 3 is detected from the following. This can be set when [Terminal 3] of the alarm is set to [Alarm input(TRM3)].
[Off]:Interlock operation is not performed even if terminal alarm 3 is detected.
1~256:Select the preset position registered beforehand to move to the position when terminal alarm 3 is detected.
[Patrol 3]:When terminal alarm 3 is detected, patrol starts. *When Patrol 3 is not registered, it is not displayed.

[VMD alarm]
Select the action to be linked to the alarm detected by the motion detector from the following.
[Off]:When an alarm is detected by the motion detector, interlock operation is not performed.
1~256:Selecting the preset position registered beforehand moves the watch to the position when an alarm is detected by the motion detector.
[Patrol 1]:When an alarm is detected by the motion detector, a patrol is started. *When Patrol 1 is not registered, it is not displayed.
[Scene change detection (SCD) alarm]
Select the action to be interlocked when an alarm is detected by the undesired signal detection from the following.
[Off]:Interlock operation is not performed even if an alarm is detected by undesired signal detection.
1~256:When the preset position registered in advance is selected, the watch moves to the preset position when an alarm due to disturbance detection is detected.
[Patrol 1]:When an alarm is detected by the disturbance detection, a patrol is started. *When Patrol 1 is not registered, it is not displayed.
[Audio detection alarm]
Select the action to be linked to the alarm detected by the sound detection from the following.
[Off]:The product does not perform interlocked operation even if an alarm is detected by sound detection.
1~256:When the preset position registered in advance is selected, the watch moves to the preset position when an alarm is detected.
[Patrol 1]:When an alarm is detected by sound detection, patrol is started. *When Patrol 1 is not registered, it is not displayed.
[Command alarm]
Select the action to be linked to the alarm by the command alarm from the following. This can be set when [Command alarm] is set to [On].
[Off]:The product does not operate in conjunction with the command alarm.
1~256:Selecting the preset position registered in advance moves the camera to the position when a command alarm is detected.
[Patrol 1]:When a command alarm is detected, a patrol is started. *When Patrol 1 is not registered, it is not displayed.
Source-specific preset position:Register the address of the sender of the command alarm and the preset position corresponding to that address, and move to that position when the alarm is detected by the command alarm.
When [Preset per sender] is clicked, a separate window opens showing the settings for the source-specific preset position.
12.4.1 Set the preset position by source (screen for setting preset position by source)
Command Alarm Action-Source Address
The IP address of the PTZ camera for the Multi-directional/PTZ integrated camera is displayed.
Operation at Command AlarmInterlocked operation
Select the action linked to the command alarm when received from the following.
[Off]:Interlock operation is not performed even if a command alarm is received.
[Alarm interlock]:Alarm operation is performed after the command alarm is received.
[Switching between black and white]:Switches between black and white after receiving the command alarm.
[Automatic Time Adjustment]:Adjusts the time after the command alarm is received.
[Note:]

・[MULTI_PTZ] Only Multi-directional cameras with integrated Multi-directional/PTZ cameras can be set to [Action at the time of a command alarm].


[Alarm E-mail notification]
When [E-mail notification setup] is clicked, the setting window for the e-mail when the alarm is generated is displayed in a separate window.
12.4.2 Mail sending when an alarm is generated
[Alarm image FTP/SFTP transmission]
When [FTP/SFTP setup] is clicked, a separate window is displayed for FTP/SFTP sending when an alarm is generated.
12.4.3 Set up FTP/SFTP transmission when an alarm is generated
[Alarm image recording(SD memory card)]
When [SD memory card setup] is clicked, the settings for recording to the SD Memory Card when an alarm is generated are displayed in a separate window.
12.4.4 Sets recording data to SD Memory Card when alarm is generated.
[TCP alarm notification]
When [TCP alarm notification setup] is clicked, the setting window for sending unique alarm notification when alarm is generated is displayed in a separate window.
12.4.5 Sets unique alarm notification when an alarm is generated.
[HTTP alarm notification]
When [HTTP alarm notification setup] is clicked, the setting window for sending HTTP alarm notification when alarm is generated is displayed in a separate window.
12.4.6 Sets HTTP alarm notification when an alarm is generated.
[SNMP transmission upon alarm detection]
When [To SNMP setting] is clicked, the setting window for sending SNMP when an alarm is generated is displayed in a separate window.
12.4.7 Set SNMP transmission when an alarm is generated.
On the [Alarm] tab of the Alarm page, press [Preset per sender >>] in [Command alarm].
12.1 [Alarm] to set alarm operation
Here, the address of the source of the command alarm and the preset position corresponding to that address are registered.
[Sender's address 1] through [Sender's address 48]
Set the IP address of the sender of the command alarm and the preset position to move corresponding to the IP address. You can set up to 48 notifications.

[Notification per Camera]
If the transmission source is a Multi-directional camera, select the camera number of the transmission source. Otherwise, select [1].

[On]/[Off] (Alarm area no. interlock)
Use [On]/[Off] to set whether or not to link with [Alarm area No.].

[Alarm area No.]
When [Alarm Area No. Interlock] is set, select the sender alarm area No. from 1 to 8.

[On]/[Off] (Reception setting during live view)
On/Off is used to select whether to link with the clicking operation of the live image of the Multi-directional camera.

[Close] buttons
Click this button to close the Source-Specific Preset Position window.
On the [Alarm] tab of the Alarm page, press [E-mail notification setup] in [Camera action on alarm].
12.1 [Alarm] to set alarm operation
Refer to the following for the setting method.
14.2.1 Set mail sending
On the [Alarm] tab of the Alarm page, press [FTP/SFTP setup] in [Camera action on alarm].
12.1 [Alarm] to set alarm operation
Refer to the following for the setting method.
14.2.2 Configuring FTP/SFTP transmission function
[Note:]

・Only models with FTP/SFTP functions can be set.


・Refer to the catalog specifications for the functions installed in each model.


On the [Alarm] tab of the Alarm page, press [SD memory card setup] in [Camera action on alarm].
12.1 [Alarm] to set alarm operation
Refer to the following for the setting method.
8.2 [SD memory card] for setting SD Memory Cards
On the [Alarm] tab of the Alarm page, press [TCP alarm notification setup] in [Camera action on alarm].
12.1 [Alarm] to set alarm operation
Refer to the following for the setting method.
12.10.1 Set unique alarm notification
On the [Alarm] tab of the Alarm page, press [HTTP alarm notification setup] in [Camera action on alarm].
12.1 [Alarm] to set alarm operation
Refer to the following for the setting method.
12.10.2 Set the HTTP alarm notification
On the [Alarm] tab of the Alarm page, press [To SNMP setting] in [Camera action on alarm].
12.1 [Alarm] to set alarm operation
Refer to the following for the setting method.
14.2.7 Set SNMP
Click [VMD area] on the Alarm page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
Here, the area for detecting the movement of an object using the motion detector function is set. An alarm is activated when the movement of an object in the set area is detected.
[Note:]

・[PTZ] Up to four areas can be set for each preset position (up to 256).


・[PTZ] You can also set the alarm operation when the camera is at a position other than the preset position.


・[MULTI] [Compact] Up to four areas can be set for each camera.


・[New X Fixed-8MP][New X Fixed-6MP][New X Fixed-5MP]If [Image capture mode] is set to [60fps Mode] or [50fps Mode], [VMD] cannot be used.


[Important]

・When the motion detector function is used to detect the movement of an object, [Alarm notification] is displayed for confirmation.
2.3.2 About live image pages


・[Alarm notification] is also displayed when the alarm input is received with the terminal alarm or when the command alarm is received.


・Depending on the network environment, notification may be delayed.


・If the [Image capture mode] of the [Basic] tabs is changed after the operation detection area is set, the operation detection area may be misaligned. Be sure to check the setting of the motion detection area again.


・When [Intelligent Auto] is set to [On], the operation detection alarm may be generated because the brightness of the entire image changes depending on the subject's condition. In this case, set one of the following settings.
-Set [Illumination detection suppression] to [On] for motion detection.
-Adjust the slider bar of the [Detection sensitivity] in the motion detection area to the [Low] direction.
Adjust the [Face priority level (Brightness)] slider bar of the intelligent auto to [-].


・The motion detector function is not intended to prevent theft, fire, etc. We will not be liable for any accident or damage.


Position Selection and Information Addition Setting Screen
[Note:]

・[PTZ]Only the PTZ camera can be set for position selection and information addition setting screen.


Operation detection area setting

[Select a preset position]
Select the preset position number for which the motion detection area is to be set and press [Start] to set the motion detection area.
Select [except the preset positions] to set the operation detection area other than the preset position.

Addition of motion detection information

[Information addition]
Sets whether to send the superimposed image data by [On] or [Off] by adding motion detection data to the image.
The operation detection information can be used by some of the search functions of the network disk recorder manufactured by us.
For details of the functions and settings, refer to the instruction manual of the connected device.
Operation detection area setting screen
Compact Dome cameras, New X Fixed Cameras
[Area]
When the motion detection area is selected in the image, it is set in order from Area 1.

[All areas] buttons
Clicking this button selects the entire area as the motion detection area and sets it to the [1(White)] of [Area].

[Status]
Enable/disable operation detection.
[Enable:Operation detection is performed.
[Disabled:Operation detection is not performed.

[Detection area]
Set the area for detecting movement of object in the motion detection area with the slider bar. The smaller the set value, the smaller the object movement will be detected. The current setting (1 to 10) is displayed to the right of the slider bar.

[Detection sensitivity]
Use the slider bar to set the sensitivity for detecting movement in the area. Individual settings can be made for each area. The larger the set value, the easier it is to sense the movement.
The current setting (1 (Low) to 15 (High)) is displayed under the slider bar.

[Delete] buttons
Click the area button to delete the area frame.

[Light detection control]
Use the [On] and [Off] buttons to specify whether or not the operation is not detected due to changes in the illumination.
[Important]

・If the lighting intensity is small, it may be impossible to suppress it.


・When the illumination detection suppression is set to [On] and a object movement is detected throughout the window, operation detection may not be performed.


・If [Camera title on screen display] is set to [On], the accuracy of motion detection may be reduced.


[Area No. notification]
Clicking [TCP alarm notification setup >>] displays the [Transmission] tabs on the Alarm Page.
12.1 [Alarm] to set alarm operation
Addition of motion detection information
[Information addition]
Adds motion detection information to images and sets on/off whether to transmit superimposed image data. The operation detection information can be used by some of the search functions of the network disk recorder manufactured by us. For details of the functions and settings, refer to the instruction manual of the connected device.
PTZ camera
[Area]
When the motion detection area is selected in the image, it is set in order from Area 1.

[All areas] buttons
Clicking this button selects the entire area as the motion detection area and sets it to the [1(White)] of [Area].

[Status]
Enable/disable operation detection.
[On]:Operation detection is performed.
[Off]:Operation detection is not performed.

[Detection area]
Set the area of the slider bar to detect movement of the subject in the motion detection area. The smaller the set value, the smaller the movement of the subject is detected. The current setting (1 to 10) is displayed to the right of the slider bar.

[Detection sensitivity]
Use the slider bar to set the sensitivity for detecting movement in the area. Individual settings can be made for each area. The larger the set value, the easier it is to sense the movement.
The current setting (1 (Low) to 15 (High)) is displayed under the slider bar.

[Delete] buttons
Click the area button to delete the area frame.

[Light detection control]
Use the [On] and [Off] buttons to specify whether or not the operation is not detected due to changes in the illumination.
[Important]

・If the lighting intensity is small, it may be impossible to suppress it.


・When the illumination detection suppression is set to [On] and the subject with movement throughout the screen is detected, the operation detection may not be performed.


[Area No. notification]
Clicking [TCP alarm notification setup] displays the [Notification] tabs on the Alarm Page.
12.1 [Alarm] to set alarm operation
Addition of motion detection information
[Information addition]
Adds motion detection information to images and sets on/off whether to transmit superimposed image data. The operation detection information can be used by some of the search functions of the network disk recorder manufactured by us. For details of the functions and settings, refer to the instruction manual of the connected device.
Multi-directional camera
[Camera selection]
Select the camera to set the area from each camera.

[Area]
When the motion detection area is selected in the image, it is set in order from Area 1.

[Status]
Enable/disable operation detection.
[On]:Operation detection is performed.
[Off]:Operation detection is not performed.

[Detection area]
Set the area of the slider bar to detect movement of the subject in the motion detection area. The smaller the set value, the smaller the movement of the subject is detected. The current setting (1 to 10) is displayed to the right of the slider bar.

[Detection sensitivity]
Use the slider bar to set the sensitivity for detecting movement in the area. Individual settings can be made for each area. The larger the set value, the easier it is to sense the movement.
The current setting (1 (Low) to 15 (High)) is displayed under the slider bar.

[Delete] buttons
Click the area button to delete the area frame.

[Light detection control]
Use the [On] and [Off] buttons to specify whether or not the operation is not detected due to changes in the illumination.
[Important]

・If the lighting intensity is small, it may be impossible to suppress it.


・When the illumination detection suppression is set to [On] and the subject with movement throughout the screen is detected, the operation detection may not be performed.


[Area No. notification]
Clicking [TCP alarm notification setup] displays the [Notification] tabs on the Alarm Page.
12.1 [Alarm] to set alarm operation
Addition of motion detection information
[Information addition]
Sets whether to send the superimposed image data by [On] or [Off] by adding motion detection data to the image. The operation detection information can be used by some of the search functions of the network disk recorder manufactured by us. For details of the functions and settings, refer to the instruction manual of the connected device.
Set the motion detection area.
[Important]

・All alarms are not detected while the setting is being changed on the setting screen. Close the setting screen after setting is completed.


1
When you drag the mouse on the image and specify an area, the specified area is set to Area [1(White)] and a frame is displayed.
Areas are set from the first to the first area number. The color next to the area number indicates the corresponding color of the frame. In addition, the frame [Status] to be set for the area becomes [On].
2
Set the [Detection area] [Detection sensitivity] with the slider bar. For [Detection area] [Detection sensitivity], see the following.
12.5 [VMD area] for setting motion detection
The area displayed and the movement detection status at the detection sensitivity are displayed in [Detection area]. Modify areas and [Detection area] [Detection sensitivity] as required.
3
When you are finished, press [Set].
[Important]

・If you do not press the [Set] buttons, the settings will not be confirmed.


4
To disable the motion detection area, change the [Status] of the area in question to [Off] and click [Set]. The disabled box will be dotted.
When disabled, no alarm is generated even if there is a change in the area.
5
To delete an area for motion detection, click [Delete] in the area to delete to delete the area frame.
6
When [Set] is clicked, the settings are reflected in the computer.
[Note:]

・[New X Fixed-8MP][New X Fixed-6MP][New X Fixed-5MP]If [Image capture mode] is set to [60fps Mode] or [50fps Mode], [SCD] cannot be used.


This section sets the disturbance detection function.
The jamming detection function activates an alarm when the camera detects a change in the subject by covering the camera with a cloth or a lid or changing the orientation of the camera significantly. You can set up one area. When disturbance is detected in the set area, an alarm is activated.
[Important]

・In the following cases, the undesired signal detection function will not work for a while.
After turning on the power
-after changing the undesired detection setting
-when the image angle of the machine changes


・When a disturbance is detected using the disturbance detection function, [Alarm notification] is displayed for confirmation.
2.3.2 About live image pages


・[Alarm notification] is also displayed when an alarm input is received with a terminal alarm or other alarm such as an operation detection alarm is generated.


・If you configure the disturbance detection area and then change the [Image rotation] or [Image] tab [Image capture mode] on the [Basic] tab, the disturbance detection area may shift. Be sure to reconfirm the settings of the disturbance detection area.


・In the following cases, disturbance detection may not be detected.
If only part of the screen is covered or transparent
-when the camera is oriented in a similar manner before and after the camera
-if a privacy zone is set


・If the [Detection Time] setting of the disturbance detection function is shorter than the [Dwell time] setting of the [Black-and-white switching], the disturbance detection alarm may be generated when the color image and black-and-white image are switched. The [Detection Time] setting of the disturbance detection function can be improved by making it longer than the [Dwell time] of [Black/white switching].


・When the color of the image is close to monochrome, it is difficult to detect disturbance. If undesired detection is difficult, increase the [Detection sensitivity] setting of the undesired detection function or increase the area of the undesired detection function.


・When [Intelligent Auto] is set to [On], the undesired detection alarm may be generated because the brightness of the entire image changes depending on the subject's condition. In this case, set one of the following settings.
-Set [Detection sensitivity] to a low setting.
-Set [Detection Time] for a long time.
-Adjust the [Face priority level (Brightness)] slider bar of the intelligent auto to [-].


・The disturbance detection function is not used to prevent theft, fire, etc. We will not be liable for any accident or damage.


[Camera selection]
Select the camera to set the area from each camera.
[Note:]

・[MULTI] [Camera selection] can be selected only for Multi-directional cameras.


[Area]
Set the disturbance detection area in the image.
[All areas]
Click this button to set the entire area as a disturbance detection area.
[Status]
Use the [On] and [Off] buttons to specify whether or not to perform undesired detection.
[On]: Detects disturbance.
[Off]: No disturbance detection is performed.
[Detection area]
Set the area for detecting movement of the subject in the disturbance detection area to [Small], [Middle] and [Large].
[Detection sensitivity]
The sensitivities for detection of disturbance in the area are set from [Very Low], [Low], [Middle], and [High].
[Detection Time]
Sets the time from when the subject changes to when the disturbance detection alarm is activated. The alarm does not operate when the subject changes only within the set time.
[3s]/ [5s]/ [10s]/ [30s]/ [1min]
[Delete] buttons
Click to delete the area frame.
Addition of undesired detection information
[Information addition]
Set [On] and [Off] to send superimposed image data by adding undesired detection data to the image.
[Note:]

・Additional disturbance detection information is not used by our network disk recorders (as of April 2022).


Set the disturbance detection area.
[Important]

・All alarms are not detected while the setting is being changed on the setting screen. Close the setting screen after setting is completed.


1
Select the camera from which the area is to be set by [Camera selection].
[Note:]

・[MULTI] [Camera selection] can be selected only for Multi-directional cameras.


2
When you drag the mouse on the image and specify an area, the specified area is set to the area (white) and a frame is displayed. In addition, [Status] becomes [On].
3
Set [Detection area] [Detection sensitivity] [Discovery Time]. For [Detection area] [Detection sensitivity], refer to the following.
12.7 [SCD area] to set up undesired detection
Change the area or [Detection area] [Detection sensitivity] as required.
4
When you have finished setting, press [Set].
[Important]

・If you do not press the [Set] buttons, the settings will not be confirmed.


5
To disable the disturbance detection area, change [Status] to [Off] and press [Set]. Click this button to display a dotted line with the disabled frame color. When disabled, no alarm is generated by undesired disturbance detection.
6
To delete the undesired detection area, press [Delete]. Click to clear the area frame.
7
When [Set] is clicked, the settings are reflected in the computer.
Click [Audio detection] on the Alarm page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
Here, the sound detection setting is performed.
[Note:]

・[New X Fixed-8MP][New X Fixed-5MP] If [Image capture mode] is set to [60fps Mode] or [50fps Mode], [Audio detection] cannot be used.


[Important]

・When the sound detection function is used to detect sound, [Alarm generation notification] is displayed so that the sound detection is confirmed.


・[Alarm notification] is also displayed when the alarm input is received with the terminal alarm or when the command alarm is received.


・Depending on the network environment, notification may be delayed.


・The sound detection function is not suitable for applications that require high reliability at all times (systems designed to prevent problems). We will not be liable for any accident or damage.


[Audio detection]
ON/OFF is used to specify whether or not to perform sound detection.
[On]:Sound detection is performed.
[Off]:Sound detection is not performed.

[Detection sensitivity]
Select the sensitivity of detection from the [Low] [Middle] [High].
[Note:]

・When installing cameras indoors, it is recommended that [Sense Level] be set to [Low].


[AI analytics target]
Select the target for detecting AI tone identification.
• [Gunshot]: Detects gunshot, explosive, shock and bursting sounds.
• [Yell]: It detects human screams and crys.
• [Vehicle horn]: Detects the horn of the car.
• [Glass break]: Detects the cracking of windows.
[Other]: Detects other sounds than gunshot, screech, horn, or cracking of glasses.
[Note:]

・In the following cases, the target sound may not be detected.
-if the duration of the cry/horn/glass break is shorter than 1 second
When the difference between the noise of interest and ambient noise is less than 6 dB
If the rain hits the camera microphone directly


・When multiple types of target sounds are generated at the same time, only one type of alarm is notified.


・The message ID of the unique alarm notification for AI sound identification is as follows.
Used for registering sound identification alarms with a recorder or our video monitoring software.
BOOK: 70
--a broken glass: 71
-horn: 72
--shriek: 73
Other: 55


・When an alarm notification for AI sound identification is received by a recorder, etc., the alarm cannot be received by a recorder etc. during the alarm mask period.


Click [Notification] on the Alarm page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
This is used to set the unique alarm notification and HTTP alarm notification.
Unique alarm notification
[TCP alarm notification]
ON/OFF is used to specify whether or not to perform unique alarm notification in the following cases.

・When an alarm is generated (unique alarm notification destination: [Alarm] field)


・When notifying the remaining capacity of the SD Memory Card (unique alarm notifying destination: [Diag.] field)


・When there is insufficient space on the SD Memory Card (unique alarm notification destination: [Diag.] field)


・When recognizing an SD Memory Card error (Original alarm notification destination: [Diag.] field)


・When writing to SD Memory Card is failed (unique alarm notification destination: [Diag.] field)


・Upon expiration of the trial period of the function extension software (original alarm notification destination: [Diag.] field)


[Note:]

・Notification of unique alarms is made in the order from [Notify Party 1] (only when checked in the [Alarm] or [Diag.] field).


[Additional alarm data]
Sets ON/OFF whether the detection area number of the operation detection alarm is notified by the unique alarm.
[Destination port]
Set the receiving port number of the unique alarm notification destination.
Settable range:1~65535
The following port numbers cannot be set because they are used by this computer.
20、21、22、23、25、42、53、67、68、69、80 110、123、161、162、443、554、995、1883、8883、10669、10670、59000~61000
[Note:]

[MULTI] The port numbers 32768 to 49151 cannot be set.


[Retry times]
Set the number of retries when the unique alarm notification cannot be performed.
Settable range:0~30
Destination of notification
PTZ camera, Compact Dome camera, New X Fixed Cameras
[Note:]

・Only PTZ cameras are displayed for auto-tracking.


[Address 1] ~ [Address 8]
Set the unique alarm notification destination with IP address or host name. You can set up to 8 notification destinations.
[Alarm] field:When the checkbox is checked, the alarm will be notified.
[Diag.] field:When checked, notification of the remaining capacity of the SD Memory Card, lack of free space of the SD Memory Card, SD Memory Card recognition error, SD Memory Card write error, and expiration of the trial period of the function extension software are notified.
[Destination server address] field:Enter the IP address or host name of the notification destination.
Input Characters:One-byte alphanumeric and one-byte symbols: . _ ‑
To delete the specified notification destination, press [Delete] for the notification destination to be deleted.
[Auto track cooperation]
ON/OFF is used to set whether or not automatic tracking linkage is set.
When [Auto track cooperation] is set to [On], alarm notification is executed only when [Alarm Area No.] matches the [Alarm area] number set for auto-tracking alarm. Alarm notification other than the automatic tracking alarm is not performed. When using the Auto Tracking Coordination function, set the alarm area condition in Auto Tracking to [On].
[Alarm area No.]
Settable range:1~4
[Important]

・If you want to enter a hostname for [Destination address], you must configure the DNS on the [Network] tab of the network page.
14.1 Networking [Network]


・Make sure that the notification destination is set correctly. If the notification destination does not exist, a proprietary alarm notification delay or transmission failure may occur.


Multi-directional camera
[Address 1] ~ [Address 48]
Set the unique alarm notification destination with IP address or host name. You can set up to 48 notifications.
[Alarm] field:When the checkbox is checked, the alarm will be notified.
[Diag.] field:When checked, notification of the remaining capacity of the SD Memory Card, lack of free space of the SD Memory Card, SD Memory Card recognition error, SD Memory Card write error, and expiration of the trial period of the function extension software are notified.
[Destination server address] field:Enter the IP address or host name of the notification destination.
Input Characters:One-byte alphanumeric and one-byte symbols: . _ ‑
To delete the specified notification destination, press [Delete] for the notification destination to be deleted.
[Notification per Camera]
ON/OFF is used to specify whether or not to execute the transmission setting by camera.
When [Notification per Camera] is set to [On], [Camera No.] is notified when [Camera No.] matches the number of the camera that generated the operation detection alarm or when [Camera No.] matches the camera number of the clicked live display.
[Note:]

[MULTI] This item is not displayed when [Image capture mode] is in Quad/Dual mode.


[camera No.]
Settable range: 1 to 4
[Note:]

[MULTI] This item is not displayed when [Image capture mode] is in Quad/Dual mode.



[Notification per VMD area]
ON/OFF is used to set whether the operation detection area-specific transmission is set.
When [Notification per VMD area] is set to [On], alarm notification is executed only when [Alarm Area No.] matches the [Alarm area] number set for the operation detection alarm. Alarm notification other than the operation detection alarm is not performed. When using the operation detection area-specific transmission function, set the alarm area status for operation detection to [On].
[Alarm area No.]
Settable range:1~8
[Important]

・If you want to enter a hostname for [Destination address], you must configure the DNS on the [Network] tab of the network page.
14.1 Networking [Network]


・Make sure that the notification destination is set correctly. If the notification destination does not exist, a proprietary alarm notification delay or transmission failure may occur.


HTTP alarm notification
[Address 1] ~ [Address 5]
Set the IP address or host name of the HTTP server that notifies the HTTP alarm. You can set up to 5 notification destinations.
Input Characters:One-byte alphanumeric and one-byte symbols: . _ ‑
Example of entry:
Http://IP address: port number or http://host name: port number
Https://IP address: port number or https://host name: port number
[Note:]

・[MULTI_PTZ] Multi-directional camera with integrated Multi-directional/PTZ can be set up to Notification Destination 4.


[Alarm] field
When an alarm is generated, the HTTP alarm notification is executed.
[Diag.] filed
Select this to issue HTTP alarm notifications when the amount of free space remaining on the SD memory card is running low, when there is not enough free space on the SD memory card, when an SD memory card recognition error occurs, when an SD memory card write error occurs, and when the trial period for the function extension software will expire.
[Delete] buttons
When this button is clicked, all notifications, user names, passwords, and notification data set for the item are deleted.
[User name]
Enter the user name that accesses the HTTP server.
Number of characters that can be entered:0 to 63 characters
Characters that cannot be entered:Double-byte and single-byte symbols " & : ; ¥
[Password]
Enter the password to access the HTTP server.
Number of characters that can be entered:0 to 63 characters
Characters that cannot be entered:Double-byte and single-byte symbols " &
[Note:]

・Basic or Digest authentication is performed by an HTTP server authentication request.


[Notification data]
Set the notification content to be added after the HTTP server set to [Address 1] ~ [Address 5].
Input Characters:Half mark alphanumeric characters and marks
[Note:]

・If the HTTP alarm function is enabled, the authentication information (user name, password) of the HTTP server may be leaked on the network when the alarm is notified to the HTTP server.


・The number of characters to be notified (including [http://]) and [Notification data] is limited to 256 characters.


・Be sure to enter the [Notification data] from the slash (/).


・If an HTTP alarm notification fails, it is listed in the system log.


・If [Notification data] is blank and [Set] is pressed, [/cgi-bin/comarm.cgi?CMD=01] is also set.


Example:
If [/cgi-bin/comalarms.cgi?CMD=01] is set as the notification destination and [/cgi-bin/comalarms.cgi?CMD=01] is set to the notification destination, the HTTP alarm notification with http://192.168.0.100/cg i-bin/commalm.cgi?CMD=01 is executed.
[PTZ linkage operation]
This is the setting to perform the operation in cooperation with the PTZ camera. The HTTPS URL of the PTZ camera is automatically displayed.
[Alarm] field
When checked, the PTZ camera works in conjunction with the camera.
[User name]
The Multi-directional camera administrator user name is automatically displayed.
[Password]
The Multi-directional camera administrator password is automatically displayed.
[Notification data]
It is displayed as blank.
[Note:]

・[MULTI_PTZ] [PTZ interlocked operation] can be set only for Multi-directional cameras with a Multi-directional/PTZ integrated camera.