10Set PTZ

The PTZ page is used to set the camera operation, preset position, and auto tracking.
The PTZ pages consist of the [Cam. Function], [Position], [Auto track setting], and [Auto track alarm setting] tabs.
[Note:]

・The items that can be set differ depending on the function of the model.


・Refer to the catalog specifications for the functions installed in each model.


Click on the [Cam. Function] tab of the PTZ page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
This section sets the operation of the camera.
[Home position]
You can set the preset position as the home position.
When the home position is set, [H] is displayed next to the preset position number.
10.2.1 Set the preset position (preset position setting screen)
[Note:]
If you want to move to the home position when the power is turned on, set [HomePosition] to [Self return].
[Self return]
When the time set by [Self return time] has elapsed after manual operation, the camera can automatically return to one of the following modes of operation.
[Off]:Do not perform self-return.
[Home position]:After the set time has elapsed, the watch returns to the home position.
[Auto Pan]:When the set time elapses, the auto pan operation starts.
[Preset Sequence 1]:When the set time elapses, Sequence 1 operation starts.
[Preset Sequence 2]:Sequence 2 operation starts when the set time elapses.
[Preset Sequence 3]:Sequence 3 operation starts when the set time elapses.
[Patrol]:When the set time elapses, the patrol operation starts.
[Note:]
If you want to perform the above operations when turning on the power, it is convenient to use the self-turn function.
The Self-turn function works even when the Setup menu is displayed.

・[Patrol] can be set only when patrols are set.
10.2.4 Set patrol (Patrol function setting screen)


・[Preset sequence] can be set only when the preset sequence is set.
10.2.2 Set the preset sequence setting (preset sequence setting screen)


[Self return time]
After the manual operation is completed, select the time from the following to return to the operation set by [Self return].
[10s]/ [20s]/ [30s]/ [1min]/ [2min]/ [3min]/ [5min]/ [10min]/ [20min]/ [30min]/ [60min]
[Maximum optical zoom ratio]
Select the maximum zoom ratio for the optical zoom from the following. Refer to the catalog specifications for the installed optical zoom ratio.

・Optical zoom: 21x model x1/x2/x3/x4/x5/x6/x7/x8/x9/x10/x11/x12/x13/x14/x15/x16/x17/x19/x20/unlimited


・Optical zoom: 30x model x1/x2/x3/x4/x5/x6/x7/x8/x9/x10/x11/x12/x13/x14/x15/x16/x17/x18/x19/x20/x21/x22/x24/x26/x27/x28/x29/unlimited


・Optical zoom: 32x model x1/x2/x3/x4/x5/x6/x7/x8/x9/x10/x11/x12/x13/x14/x15/x16/x17/x18/x19/x20/x21/x22/x23/x24/x26/x27/x28/x30/x31/unlimited


・Optical zoom: 40x model x1/x2/x3/x4/x5/x6/x8/x8/x9/x10/x11/x12/x13/x14/x15/x16/x17/x18/x19/x20/x21/x22/x23/x24/x26/x27/x28/x29/x30/x31/x32/x33/x34/x36/x37/x38/x39/unlimited


[HD Extra optical zoom]
Select the setting of HD EX optical zoom from the following.
[On]:When the optical zoom range is exceeded, the HD EX optical zoom is performed.
[Off]:HD EX optical zoom is not performed. It is within the optical zoom range.
What is HD EX optical zoom?
Among the effective pixels of the MOS sensor, approximately 920,000 pixels (equivalent to 1280 x 720 resolution) are cut off from the center and shot. Therefore, using a resolution of less than 1280 x 720 makes it possible to shoot with a higher telephoto effect.
About HD EX optical zoom

・Optical zoom: For a 21x model, x1 to x21 optics is performed, and for more than x31 HD EX optical zoom is performed.


・Optical zoom: For a 30x model, x1 to x30 optics is performed, and for more than x90 HD EX optical zoom is performed.


・Optical zoom: For a 32x model, x1 to x32 optics is performed, and for more than x48 HD EX optical zoom is performed.


・Optical zoom: For a 40x model, x1 to x40 optics is performed, and for more than x60 HD EX optical zoom is performed.


[Digital zoom]
Select the digital zoom setting from the following.
[On]:When the optical zoom and HD EX optical zoom are exceeded, digital zoom is performed.
[Off]:Digital zoom is not performed.
About Digital zoom

・Optical zoom: For a 21x model, x1 to x21 optical zoom, x31 HD EX optical zoom, and more (up to x336) digital zoom are performed.


・Optical zoom: For a 30x model, x1 to x30 optical zoom, x90 HD EX optical zoom, and more (up to x480) digital zoom are performed.


・Optical zoom: For a 32x model, x1 to x32 optical zoom, x48 HD EX optical zoom, and more (up to x512) digital zoom are performed.


・Optical zoom: For a 40x model, x1 to x40 optical zoom, x60 HD EX optical zoom, and more (up to x640) digital zoom are performed.


[Note:]
When [On] is set to Digital Zoom, it stops once just before the Digital Zoom magnification changes during the zoom operation.
The preset position cannot be set with the digital zoom factor.
If [HD Extra optical zoom] is [Off], [Digital zoom] cannot be set to [On].
[Camera position display]
Select the information displayed in the image during manual operation from the following.
[Off]:The information is not displayed in the image.
[Pan tilt angle/magnification display]:Displays pan angle/tilt angle/magnification.
[Directional view]:Displays the direction.
[Note:]
When set to • [Pan·Tilt degree/Zoom ratio display], the pan tilt angles/magnifications are displayed in the [Camera title position] set on the Basic Page [Basic] tab.
10.2.6 Setting of pan/tilt range (pan/tilt range setting screen)
When set to • [Direction display], the orientation is displayed in the [Camera title position] you set on the [Basic] tab of the basic page.
10.2.5 Setting for direction/direction setting (direction/direction setting screen)
To select • [Direction display], set the reference northern direction with the [Direction/Angle setting] [North point setting].
10.2.5 Setting for direction/direction setting (direction/direction setting screen)
[Operation mode display]
Displays the operation mode when the camera is running automatically.
[On]:Displays the operating mode.
[Off]:The operation mode is not displayed.
Operation mode
Display
During startup
INITIAL
During auto pan
AUTO PAN
Automatic tracking (in progress)
AUTO TRACKING
During patrol
PATROL
During the preset sequence
PRESET SEQ
[Tilt-flip]
Select the tilt-flip setting from the following.
[On]:When the tilt end point (directly below) is reached during manual operation, the pan can be automatically rotated at a high speed to continue operation without stopping at the tilt end point.
[Off]:The tilt-flip function does not work.
[Note:]

• Even if the tilt-flip function is activated on the TELE side, some parts are not visible.


In the main area of the Live image pages, clicking the desired position for the center of the field angle moves the orientation of the camera to the center of the clicked position. In this case, the product continues to operate without stopping at the tilt end point.

• During flip movement, the image being moved is displayed.


[Tilt Angle]
Select the angle limit of tilt operation from the following. (Horizontal = 0°)
10°/ 5°/ 3°/ 0°/ −3°/ −5°/ −10°/ −15°/ −20°/ −25°/ −30°
[Note:]
The screen may be partially darkened if it is directed above-20 degrees.
Maximum speed of optical zoom
Select the maximum speed of the optical zoom.
[High]/[Mid]/[Low]
[Maximum panning/tilting speed]
Select the maximum speed for pan tilt operation.
[1°/s], [2°/s], [5°/s], [10°/s], [25°/s], [50°/s], [90°/s], [135°/s], [150°/s], [300°/s], [400°/s], [500°/s], [600°/s], [Unlimited]
[Focus distance]
If you have a object over the window or a different object over a short distance, it may be difficult to focus on the object you want to view. If the camera is not focused properly, you can limit the shortest shooting distance.
[Unlimited]/[1.5m]/ [3m]/ [5m]/ [10m]
[Auto position refresh]
Turning on the Auto position refresh, when the panning (turning) angle deviates by a certain amount, so that it will automatically shift to the positive position.
[On]:Perform position refresh automatically.
[Off]:Not perform position refresh automatically.
Click on the [Position] tab of the PTZ page. Refer to the following how to display and operate the Advanced menu.
5.1 How to display
5.2 How to operate
To Advanced Settings for each item>>Clicking this button displays the advanced settings window in a separate window and allows you to set the settings while viewing the images displayed on the [Position] tab.
Here, you can set the image quality adjustment, preset position, preset sequence setting, auto pan, patrol, direction/direction setting, and pan/tilt range setting.
[Preset position]
To Advanced Settings>>When the button is clicked, the preset position setting window is displayed in a separate window.
10.2.1 Set the preset position (preset position setting screen)

[Preset sequence setting]
To Advanced Settings>>When the [button] is clicked, the preset sequence settings window is displayed in a separate window.
10.2.2 Set the preset sequence setting (preset sequence setting screen)

[Auto pan]
To Advanced Settings>>Click the [Auto Pan] button to display the auto pan setting window in a separate window.
10.2.3 Set auto pan (Auto pan setting screen)

[Patrol]
To Advanced Settings>>When the [Patrol] button is clicked, the setting window for the patrol is displayed in another window.
10.2.4 Set patrol (Patrol function setting screen)

[Direction/Angle]
To Advanced Settings>>When the button is clicked, the setting window for direction/direction setting is displayed in a separate window.
10.2.5 Setting for direction/direction setting (direction/direction setting screen)

[Pan/tilt range setting]
To Advanced Settings>>Click the [Button] button to open a window for specifying the pan/tilt range.
10.2.6 Setting of pan/tilt range (pan/tilt range setting screen)
In the [Position] tab of the PTZ-page to the Advanced Settings tab of [Preset position]>>Click the [Button].
10.2 [Position] for setting positions
Here, you can register, change, or delete the preset position.
If you adjust the focus, brightness, zoom, etc., the images on the [Position] tabs will be reflected at the same time.
[Important]

・Do not change other settings during preset position setting. The image may not be displayed correctly.


・The preset position cannot be set with the magnification of the digital zoom.


・Up to 256 preset positions can be set.


[Note:]

・Depending on the operating environment (+5 °C or less as a guideline), the speed of the preset movement may be slightly slower.


Preset position setting
[Preset ID]
Use [On] and [Off] to set whether the position name is displayed. You can set for each preset position.
[On]:Displays the position name.
[Off]:The position name is not displayed.
[Important]

・If you have configured [Preset ID (0 – 9,A – Z)] and [Preset ID], be sure to press [Register].


[Note:]

・When set to [On], the position name is displayed where you set the position in [Camera title position] on the [Basic] tab.


[Preset ID (0 – 9,A – Z)]
Enter the name to be displayed on the image. You can set for each preset position.
Number of characters that can be entered:0 to 40 characters
Input Characters:0-9 (single-byte), A-Z (single-byte, uppercase, lowercase), double-byte, single-byte symbol ! " # $ % & ' ( ) * + , ‑ . / : ; = ?
[Note:]

・The position name entered is displayed next to the preset position number in the pull-down. If [Preset ID] is set to [On], it can also be displayed on the images.


[Auto focus]
Use [Auto] and [Off] to set whether auto focus is performed after the preset is moved. You can set for each preset position.
[Auto]:Auto focus is performed after the preset is moved.
[Off]:Auto focus is not performed after moving the preset.
[Note:]

・When presetting a subject whose depth does not change, a subject whose contrast is low, or a subject with high brightness such as a spotlight, etc., set [Off] and register the preset position after setting the focus.


[Dwell time]
During the preset sequence operation, select the time to reflect the image of each preset position (the time when the camera stops rotating) from the following.
[5s]/ [10s]/ [15s]/ [20s]/ [25s]/ [30s]
[Note:]

・The preset position set to [Off] does not move to that position during the preset sequence, but instead moves to the next preset position.


・Depending on the stop time setting, the watch may move to the next preset position during auto focus operation.


・If the preset sequence function is used for a long time, the drive parts may be consumed and the replacement cycle of consumables may be faster. For consumables, refer to the Web Guide.


[Super Dynamic]
You can set [On] or [Off] to activate the super dynamic function. You can set for each preset position.
This cannot be set when [Image capture mode] is [16:9 mode(60fps mode)] or [16:9 mode(50fps mode)].
See [What is Super Dynamic] for details on super dynamic.
[On]:The Super Dynamic function is activated.
[Off]:Stops the superdynamic function.
[Note:]

・Set [Super Dynamic] to [Off] when the following phenomena are observed depending on the lighting condition.
-when flickering or color changes occur
-when noise is generated in the bright area of the screen


・If [Light control mode] is set to [Fix shutter], [Super Dynamic] cannot be set to [On].


・When [Stabilizer] is set to [On], the superdynamic setting is [Off].


・[Rapid PTZ-8M (4K)][Rapid PTZ-6M]If you switch the [Super Dynamic] from [On] to [Off] or from [Off] to [On], the images may be distorted.


[Level]
Adjust the superdynamic level.
When the slider bar is moved in the [+] direction, you can shoot a subject with a large difference in light and darkness without flipping white or shading black.
Move the slider bar in the [-] direction to take a full picture of the middle brightness.
Press [Reset] to return to the default settings.

[BLC/ HLC]
Select from the following. This setting is not available if [Super Dynamic] is set to [On] or [Intelligent Auto] is set to [On].
[Back Light Correction (BLC)]:Enables the backlight correction function.
[Intensity correction]:Enables the high light correction function. Illumination compensation suppresses bright lighting of subjects such as car headlights during nighttime.
[Off]:Stops the backlight compensation function and the intense light correction function.

[BLC level]
Adjust the backlight correction level.
Moving the slider bar in the [+] direction improves the backlight correction effect.
Moving the slider bar in the [-] direction reduces the effect of backlight correction.
Press [Reset] to return to the default settings.

[HLC level]
Adjust the intensity correction level.
Moving the slider bar in the [+] direction improves the effect of intense light correction.
Moving the slider bar in the [-] direction reduces the effect of intense light correction.
Press [Reset] to return to the default settings.

[Mask area]
When the mask area is set, the set area can be masked and the light intensity can be adjusted. If [Super Dynamic] is set to [On], it cannot be set.
For details on how to set the mask area, refer to the following.
9.4.2 Set the mask area

[Zoom], [Focus], Control Pad/Button, [Brightness] Button
Please refer to the following instructions for operation.
9.4.6 Setting the privacy zone (Privacy zone setting screen)

[Set] buttons
Register the preset position.

[Delete] buttons
Deletes the preset position selected by the position number.

[Close] buttons
Click this button to close the preset position setting window.
Register the preset position
1
Select the position number.
[Position No.] shows the selected position number.
10.2.1 Set the preset position (preset position setting screen)
If it is already registered, the camera moves to the preset position selected.
2
Move the camera direction in the direction you want to register.
3
If you want the position name to appear on the live image page, set [Preset ID] to [On] and enter the position name.
4
Set Auto Focus or Stop Time.
5
Press [Register].
6
To set image quality for each position, set each item such as Super Dynamic. [Super Dynamic], [BLC/ HLC], and [Mask area] are reflected immediately.
[Note:]

・When registering the preset position, the camera may move slightly.


・If [Image adjust] [Scene file] is set to other than [Scene file is not applied], [Super Dynamic], [BLC/ HLC], and [Mask area] cannot be set.


To [Preset sequence setting] Advanced Settings on the [Position] tabs of PTZ pages>>Click the [Button].
10.2 [Position] for setting positions
Here, you can register, change, or delete the preset sequence.
Up to three preset sequences can be set.
Preset sequence setting
Preset Sequence 1, Preset Sequence 2, Preset Sequence 3
The preset sequence can be set.
[Select all] buttons:Select all preset positions.
[Cancel all] buttons:You can release all selections.
1~256:Enables/disables the corresponding preset position.
[Set] buttons:Save the settings of the created preset sequence.
[Note:]

・When the preset sequence is activated, the registered preset positions are moved from a younger number to a higher order.


・After moving to the trailing preset position, the system returns to the youngest number and moves the preset position back in sequence.


In the [Position] tab of the PTZ-page to the Advanced Settings tab of [Auto pan]>>Click the [Button].
10.2 [Position] for setting positions
Here, you can set auto pan.
[Note:]

・If the auto pan function is used for a long time, the drive parts may be consumed and the replacement cycle of consumables may be faster. For consumables, refer to the Web Guide.


Setting the end point
[Start position]
Use the [Zoom], [Focus] and Control Pad/Buttons to move the camera to the desired position at the left end of the auto pan, and then press the [Set] button. Zoom and focus are set at the same time.
[Note:]

・The pan, tilt, and zoom operations are also available on the images in the [Position] tabs.


[End position]
Use the Control Pad/Button to move the camera to the desired position for the right end of the auto pan, and then press the [Set] button.

Auto pan operation

[Dwell time]
Select the stop time at the start and end positions from the following.
[0s]/ [1s]/ [2s]/ [3s]/ [4s]/ [5s]/ [10s]/ [15s]/ [20s]/ [25s]/ [30s]

[Speed]
Select the pivot speed of the pan operation from the following.
[1°/s]、[2°/s]、[3°/s]、[4°/s]、[5°/s]、[7°/s]、[10°/s]、[13°/s]、[18°/s]、[24°/s]
[Important]

・If you set [Auto pan], be sure to press [Set].


[Note:]

・Even when the magnification of the digital zoom is set, the turn of the pan operation is performed at a position less than 34 times.


[Zoom], [Focus], Control Pad/Button, [Brightness], and Move presets buttons
Please refer to the following instructions for operation.
2.3.2 About live image pages

[Close] buttons
Click this button to close the auto pan setting screen.
In the [Position] tab of the PTZ-page to the Advanced Settings tab of [Patrol]>>Click the [Button]. Here, information about patrols is set.
10.2 [Position] for setting positions
The patrol function stores the pan/tilt/zoom/focus and reproduces the stored operation.
[Note:]

・If the patrol function is used for a long time, the drive parts may be consumed and the replacement cycle of consumables may be faster. For consumables, refer to the Web Guide.


Patrol setting
[Number of patrol pattern]
Select the number of memories in the patrol. The amount of time that can be stored varies depending on the number of memories.
1:The operation for 2 minutes is stored in Patrol 1.
2:The operation for one minute is stored in Patrol 1 and Patrol 2.
4:The operation for 30 seconds is stored in Patrol 1, Patrol 2, Patrol 3, and Patrol 4.
[Note:]

・When the number of memories is changed, the stored patrol operation is deleted.


[Learn patrol pattern]
Select the patrol number (1 to 4) you want to set by clicking [▼] on the [Patrol No.]. The [*] mark to the right of the patrol No. indicates that the patrol operation has already been stored.
With Patrol No selected, clicking [Learn] starts storing the camera operation. The characters of [LEARNING(***S)] are displayed during storage. ***S is the remaining time that can be stored.
When [Stop] is clicked, memory is stopped while the camera is in memory and reproducing is stopped while the camera is in reproduction. When the remaining time is 0 seconds (0S), the operation stops automatically.
With Patrol No selected, clicking the [Execute] button reproduces the stored operation of the camera.
[Note:]

・The camera operations to be stored are as follows.
-Operation start position memory
Pan tilt zoom focus position
When operating the camera
Move Pan Tilt Zoom Focus/Preset Position


・The auto focus function does not operate during the patrol operation. At this time, when zoom in from the WIDE side as a characteristic of the zoom lens, the focus is blurred. To store the zoom operation, start from the TELE side to prevent the focus from shifting.


[Zoom], [Focus], Control Pad/Button, [Brightness], and Move presets buttons
Please refer to the following instructions for operation.
2.3.2 About live image pages

[Close] buttons
Click this button to close the Patrol Settings window.
In the [Position] tab of the PTZ-page to the Advanced Settings tab of [Direction/Angle setting]>>Click the [Button]. Here, you can set the direction/direction setting. When this page is displayed, it moves to the punch position set to north.
10.2 [Position] for setting positions
Direction/Angle setting
If the [Camera position display] on the [Cam. Function] tab of the PTZ page is set to [Direction display], the 8-directions are displayed in the preset position title display position.

[North point setting]
Set the orientation to be displayed as north (N) by adjusting the orientation of the pan and pressing [Set].

[Display character setting]
Individual names can be set for each direction/direction.
[N]:Set the north direction name.
[NE]:Set the name in the northeast direction.
[E]:Set the name in the east direction.
[SE]:Set the name in the southeast direction.
[S]:Set the name in the southern direction.
[SW]:Set the name in the southwest direction.
[W]:Set the name in the west direction.
[NW]:Set the name in the northwestern direction.

[Panning 0° direction setting]
Set the direction of the pan to 0°. If you adjust the field angle with the control pad/button and click the [Set] button, the direction of the pan you are presently pointing to will be 0°. Press [Reset] to return to the default settings.
[Note:]

・Tilts are not set in the 0° direction.


・Changing the 0° direction of the pan does not change the position of the preset position already set. The set auto pan turns within the same range as before the change. Similarly, the same operation as before the change is performed for the patrol setting.


[Zoom], [Focus], Control Pad/Button, [Brightness], and Move presets buttons
Please refer to the following instructions for operation.
2.3.2 About live image pages

[Close] buttons
Click this button to close the direction/direction setting window.
In the [Position] tab of the PTZ-page to the Advanced Settings tab of [Pan/tilt range setting]>>Click the [Button].
10.2 [Position] for setting positionsHere, the range of pan tilt is set.
Pan/tilt range setting
On/Off sets whether to enable the range that restricts the pan tilt operation.
Set [On] and use the control pads/buttons to adjust the field angle to set [Left end], [Right end], [Top end] and [Bottom end].

[Left end]/[Right end]/[Top end]/[Bottom end]
Adjust the angle of view with the control pad/button and press the [Set] button to view the angle at the set position.
[Note:]

・The [Left end] angle should be smaller than the [Right end] angle and the [Bottom end] angle should be larger than the [Top end] angle.


・Set [Pan/tilt range setting] on a screen that is not zoomed in.
If you set the display size to 1.0 times (x1) on the zoomed display, a larger area than when the display was set (enlarged display) is displayed.


・Incorrect settings may cause you to view unexpected camera images. After setting, be sure to check the image using the pan tilt operation.


・Configure [Pan/tilt range setting] prior to setting the preset position. If the preset position is outside the range of [Pan/tilt range setting], the preset position stops at the end of the range.


・When the pantilt range setting screen is displayed, the zoom factor is 1.0 times.
During [Pan/tilt range setting], [PT LIMIT SETTING] is displayed in the images.
-If you do not operate for 5 minutes, the [Pan/tilt range setting] [Set] will be disabled. To continue the operation, display the [Pan/tilt range setting] window again and set it.


Click on the [Auto track setting] tab of the PTZ page.
Here, you can register, change, or delete auto tracking settings.
[Note:]

・Auto track setup is not available under the following conditions.


 -When [16:9 mode(60fps mode)], [16:9 mode(50fps mode)], [4:3 mode(15fps mode)] or [4:3 mode(12.5fps mode)] is selected for [Image capture mode]


・Under the following conditions, auto track setup is available, but the auto track performance will lower.


 -When [Maximum shutter] of [Image adjust] - [Light control mode] is set to [Max.2/30s], [Max.4/30s], [Max.6/30s], [Max.10/30s], or [Max. 16/30s].
(For auto track, the [Max.1/30s] setting is recommended.)


・If the automatic tracking function is used for a long time, the drive parts may be consumed and the replacement cycle of consumables may be faster. For consumables, refer to the Web Guide.


Automatic tracking is a function that automatically tracks and shoots an object when it is detected in a predetermined auto pan, preset sequence/preset position, patrol, or area.
Basic settings
[Detection object]
The object to be detected can be selected. You can select multiple objects.
[Human]:Automatic tracking is performed when a person is detected.
[Vehicle]:Automatic tracking is performed when a car is detected.
[Bicycle]:Automatic tracking is performed when a motorcycle is detected.

[Object size]
Select the size at tracking from the following.
[Small (1/4 of the image)]:Zoom the tracking object to the monitor screen up to about 1/4 (vertical) size.
[Medium (1/2 of the image)]:Zoom the tracking object to the monitor screen up to about 1/2 (vertical) size.
[Large (3/4 of the image)]:Zoom the tracking object to the monitor screen up to approximately 3/4 (vertical) size.
[No size adjustment]:Zoom control is not performed during tracking.
[Note:]

・The size is only a guide. Depending on the environmental conditions and tracking conditions, the assumed size may not be achieved.


・Increasing the size of the object to be tracked reduces the tracking performance.


[Sensitivity]
Select the sensitivity during tracking from the following.
[High]/[Middle]/[Low]
[Note:]

・The lower the sensitivity, the less false detection due to wooden shaking, but the lower the tracking performance. On the other hand, higher sensitivity improves tracking performance, but it also increases false detection. Set according to the environment.


[Longest tracking time]
Select the time from below from the start of auto-tracking to forced termination.
[Off(Unlimited)]/[10s]/[20s]/[30s]/[40s]/[50s]/[1min]/[2min]/[3min]/[5min]/[10min]
[Note:]

・After the maximum tracking time, the camera stops in that position. When the auto mode operation is restored, the self-return time is counted and the auto mode operation is restored after the tracking is stopped by setting the self-return.


[Auto track data in video stream]
Select whether to send the superimposed image data by adding auto-tracking information to the image.
[Off]:Automatic tracking information is not added to the image.
[On]:This feature adds automatic tracking information to images, but does not display target frames for objects under automatic tracking in live pictures.
[On (with track video display)]:This feature adds auto-tracking information to images and displays the target frame for objects under auto-tracking in live pictures.
Auto tracking start setting
[Auto pan]
Select whether or not to automatically track the user during auto panning.
[Enable]:Automatic tracking is started during auto panning.
[Disable]:Automatic tracking is not started during auto pan.

[Preset sequence/Preset position]
Choose whether to auto track in preset sequence or in preset position.
[Enable]:Automatic tracking is started during the preset sequence or in the preset position.
[Disable]:Automatic tracking is not started during preset sequence or preset position.

[Preset position selection]
[Select all] buttons:Select all preset positions.
[Cancel all] buttons:You can release all selections.
1~256:Toggle the corresponding preset position [On] or [Off].
[Set] buttons:Save the settings of the created preset sequence.

[Patrol]
Select whether or not to automatically track when a tracking target is detected during patrol.
[Enable]:Start automatic tracking during patrol.
[Disable]:Automatic tracking is not started during patrol.
Auto Track Activation Setting (Area)
[Area select]
When [Detection object] appears in the specified area, auto tracking can be started.
Eight areas can be set.
[Set] buttons:Set the auto tracking start area to the specified area No.
[Delete] buttons:Deletes the auto tracking area set to the specified area number.
[Cancel] buttons:Cancels the setting of the currently set auto tracking area.

[Zoom], [Focus], Control Pad/Button, [Brightness], and Move presets buttons
Please refer to the following instructions for operation.
2.3.2 About live image pages

[Close] buttons
Click this button to close the Auto Tracking Settings window.
[Important]

・In the following cases, the target subject may not be tracked or may malfunction.
Low contrast between the subject and the background
If the dome is moist or dirty
Large variation in illumination
When there are many movements other than the subject
When the subject moves directly below the camera
If flickering is severe
-reflection of light through windows, reflection of road surfaces, reflection of backlight into the dome, etc.
When a tracking object is hidden in the pole or behind the object.
-when multiple subjects intersect or crowd
When the subject moves too fast or too slowly
-if the subject is too small or too large
If the camera is swaying
If the weather is very bad
-when the image correction function is ON


・It is recommended to use the product in the following installation environment to increase the detection accuracy.
--more than about 1/5 (vertical) of the size of the monitor screen


・We shall not be liable for any inconvenience, damage, or damage caused by the automatic tracking function settings or the results.



Procedure for setting automatic tracking linkage
When two or more cameras with automatic tracking function are used, the tracking of objects can be coordinated between the cameras.
(Automatic Tracking Coordination Function)
As an example, as shown in the figure below, the procedure for setting the connection from Camera 1 (IP address: 192.168.0.11) to Camera 2 (IP address: 192.168.0.12) when the tracking target enters the alarm area No.1.
1
Set the alarm area for the area for which automatic tracking is desired in Camera 1.
The auto tracking setting screen is displayed.
Select [On(In preset alarm area)] in [Auto track alarm] and press [Set].
In the Alarm area [Area select], select 1 from the [Area No.] pull-down.
While looking at the screen, perform pan tilt zoom to set the alarm area.
Press [Set].
2
Set the preset position to move when receiving the unique notification command in camera 2. (Set the preset position so that the alarm area No.1 of Camera 1 set in step 1 enters the screen.)
The preset position setting screen is displayed.
10.2.1 Set the preset position (preset position setting screen)
Select the desired number from the [Preset] pull-down list.
While viewing the screen, set the preset position by using the pan tilt zoom.
Press [Register].
3
Set Camera 1 (IP address: 192.168.0.11) to notify the command.
The Alarm Page [Notification] window is displayed.
12.12 [Notification] to set alarm notification
Set [TCP alarm notification] to [On] and press [Set].
In the [Destination of notification] [Notify Destination 1] (which may be selected), check the [Alarm] checkbox and insert 192.168.0.12 in the [Destination address].
Set [Auto track cooperation] to [On] and select Alarm area No. 1.
Press [Set].
4
Set Camera 2 (IP address: 192.168.0.12) to receive the command.
The Alarm Page [Alarm] window is displayed.
12.1 [Alarm] to set alarm operation
Set the [Alarm] [Command alarm] to [On] and press [Set].
Set the [Camera action on alarm] [Command alarm] to [Preset per sender] and press [Preset per sender].
On the Preset by Source window, check Auto Tracking of [Source Address 1] (any Source Address may be selected), enter the Source Address 192.168.0.11 (Camera 1), select the preset position to move when receiving the command set in step 2, click [Set], and close the pages.
12.4.1 Set the preset position by source (screen for setting preset position by source)
Press [Set].
5
By starting the automatic tracking operation of camera 1, the automatic tracking linkage function can be used.
Click on the [Auto track alarm setting] tab of the PTZ page. Here, you can set the automatic tracking alarm.
[Note:]

・Automatic tracking is not available in the following cases.
-When [Image capture mode] is [16:9 (60 fps mode)], [16:9 (50 fps mode)], [4:3 (15 fps mode)], [4:3 (12.5 fps mode)]
-When the [Light control mode] [Maximum shutter] of [Image adjust] is set to the following
Maximum 2/30s/Maximum 4/30s/Maximum 6/30s/Maximum 10/30s/Maximum 16/30s


・If the automatic tracking function is used for a long time, the drive parts may be consumed and the replacement cycle of consumables may be faster. For consumables, refer to the Web Guide.


The auto tracking function automatically tracks and shoots the subject when movement is detected in the pre-set alarm area.
[Auto track alarm]
Select the alarm during automatic tracking from the following.
[Off]:Alarm is not output.
[On (Immediate)]:During automatic tracking, the alarm will continue to be output. The output interval is every 5 seconds.
[On (After alarm wait time)]:The alarm is output only once when automatic tracking continues for a certain period of time.
[On (In preset alarm area)]:During automatic tracking, the alarm is output only once when a tracking object is in the set alarm area. Refer to [Alarm area] for the alarm settings.

[Alarm wait time]
If [Auto track alarm] is set to [On(After alarm wait time)], select the set time from the following.
[1s]/ [10s]/ [30s]/ [1min]/ [3min]/ [5min]

Alarm area

[Area select]
Click [▼] on the [Area No.] and select the area number (1 to 8) to be set. The [*] mark to the right of the area No. indicates that the area is already stored. The alarm area is enabled when On (when the alarm area enters) is selected for automatic tracking alarm.

[Area No. notification]
Clicking [TCP alarm notification setup] displays the [Notification] tabs on the Alarm Page.
12.12 [Notification] to set alarm notification
[Note:]

・The alarm area cannot be set individually for each preset position. The configured area is valid for all preset positions.