1 Select the position number. [Position No.] shows the selected position number. →10.2.1 Set the preset position (preset position setting screen) If it is already registered, the camera moves to the preset position selected. 2 Move the camera direction in the direction you want to register. 3 If you want the position name to appear on the live image page, set [Preset ID] to [On] and enter the position name. 4 Set Auto Focus or Stop Time. 5 Press [Register]. 6 To set image quality for each position, set each item such as Super Dynamic. [Super Dynamic], [BLC/ HLC], and [Mask area] are reflected immediately. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 Set the alarm area for the area for which automatic tracking is desired in Camera 1. ① The auto tracking setting screen is displayed. ② Select [On(In preset alarm area)] in [Auto track alarm] and press [Set]. ③ In the Alarm area [Area select], select 1 from the [Area No.] pull-down. ④ While looking at the screen, perform pan tilt zoom to set the alarm area. ⑤ Press [Set]. 2 Set the preset position to move when receiving the unique notification command in camera 2. (Set the preset position so that the alarm area No.1 of Camera 1 set in step 1 enters the screen.) ① The preset position setting screen is displayed. →10.2.1 Set the preset position (preset position setting screen) ② Select the desired number from the [Preset] pull-down list. ③ While viewing the screen, set the preset position by using the pan tilt zoom. ④ Press [Register]. 3 Set Camera 1 (IP address: 192.168.0.11) to notify the command. ① ② Set [TCP alarm notification] to [On] and press [Set]. ③ In the [Destination of notification] [Notify Destination 1] (which may be selected), check the [Alarm] checkbox and insert 192.168.0.12 in the [Destination address]. ④ Set [Auto track cooperation] to [On] and select Alarm area No. 1. ⑤ Press [Set]. 4 Set Camera 2 (IP address: 192.168.0.12) to receive the command. ① ② Set the [Alarm] [Command alarm] to [On] and press [Set]. ③ Set the [Camera action on alarm] [Command alarm] to [Preset per sender] and press [Preset per sender]. ④ On the Preset by Source window, check Auto Tracking of [Source Address 1] (any Source Address may be selected), enter the Source Address 192.168.0.11 (Camera 1), select the preset position to move when receiving the command set in step 2, click [Set], and close the pages. →12.4.1 Set the preset position by source (screen for setting preset position by source) ⑤ Press [Set]. 5 By starting the automatic tracking operation of camera 1, the automatic tracking linkage function can be used. |
|
|
|
|
|