3.Basic settings

1)
After installing the "AI Processing Relay", an entry for "AI Processing Relay" will be added to the "Ext. software" tab of the "Setup" > "Detailed setting" page of the WV-S71300-F3.
2)
Click the "Setup" button to open the setting screen.
3)
Enter information about the camera to be linked to this product.
-
Camera username
Enter the username that has been set for the camera to be linked.
Default setting: blank
-
Camera password
Enter the camera password that has been set for the camera to be linked.
Default setting: blank
-
Protocol
Select the protocol used to access the linked camera from this product.
Default setting: HTTP
-
IP address
Enter the IP address assigned to the camera to be linked.
Default setting: blank
-
Port number
Enter the port number of the protocol to be used for the linked camera.
Default setting: blank
-
Http Jpeg stream URL
Enter the command to receive the MJPEG data from the linked camera.
Enter the command after the IP address of the camera.
Do not enter a leading "/". The leading "/" will be automatically completed by this product.
In the case of a multi-sensor camera, please include the channel specification in the command.
Default setting: blank

Example: i-PRO camera (single-lens camera)
cgi-bin/mjpeg?stream=1&frame=5
-
Channel
Enter the channel of the camera to be linked, using a number between 1 and 4. Enter 1 if the camera to be linked is a single-lens camera. If the camera to be linked is a multi-sensor camera, enter the channel to acquire MJPEG data. The information entered in this field is used when connecting to the i-PRO Active Guard.
Default setting: 1
- Enter the information for the camera to be linked, not the information for the WV-S71300-F3, in the configuration fields for this product.
4)
Press the "Set" button
5)
Enter username and password
An alert will appear asking you to enter a username and password. Enter the username and password for the camera to be linked and press the "Sign in" button.
- The username and password entered for the alert must be the username and password of the camera to be linked, not the username and password of the WV-S71300-F3.
6)
The results received from the linked cameras are displayed in the Result column.
-
Http jpeg stream full URL
Displays the URL to receive MJPEG data from the linked camera.
-
Received image
The image of MJPEG data received from the linked camera is displayed. The image is updated at 1 fps regardless of the received frame rate.
-
Resolution
The resolution of the MJPEG data received from the linked camera is displayed. The resolution of the camera to be linked must be set to 1920x1080 or 1280x720.
-
Framerate
Displays the frame rate of the MJPEG data received from the linked camera. 4.0 to 6.0 is the recommended value. If the recommended value is not displayed, change the frame rate of the linked camera to 5fps. If the value displayed in Framerate is lower than the recommended value even after setting the frame rate of the linking camera to 5fps, lower the bit rate of the MJPEG data from the linking camera.
- The WV-S71300-F3 should be used in its default settings.
Please refer to the manual of each extension software to set up the software. An alert may appear when opening the extension software screen. Enter the username and password of the camera to be linked to the alert. The live image of the linked camera will be displayed on the configuration screen of the extension software.
- The username and password for the alert must be the username and password of the camera to be linked, not the username and password of the WV-S71300-F3.
- AI-VMD Mode selection should be set to "Normal angle mode".
- iCT does not display the live image of the linked camera. Please set the area settings, etc. from the link displayed in iCT.
Refer to the i-PRO Active Guard manual for i-PRO Active Guard settings. Only the contents related to the linkage of this product are explained below.
1)
Click "Camera Registration".
2)
Select "Add" - "Add AI Processing Relay App".
3)
Enter the IP address and authentication information for the camera in which this product is installed, and click "Check" and "Register".
4)
Click "Restart" to restart the i-PRO Active Guard server.
The following settings must be made in advance.
- 3.1 Configure this product
- Registration of cameras to be linked with this product to VMS. However, cameras installed this product do not need to register to VMS.
If you use Genetec / Milestone VMS, you need to configure the following settings to notify alarms. i-PRO Active Guard will notify Genetec / Milestone VMS of the AI-VMD and AI Occupancy Detection alarms by making the following settings. If you use Video Insight VMS, you do not need the following settings.
(1)
Open i-PRO Active Guard's VMS server screen and press the "Add" button.
(2)
Press the "Test" button after entering the VMS information. When "Success" is displayed, press the "Save" button.
-
Type
Select Genetec Security Center or Milestone XProtect.
-
IP address
Enter the IP address of Genetec Security Center or Milestone XProtect.
-
WEB API Port
Enter the port number of the Genetec Security Center or Milestone XProtect.
-
Notification Port (Milestone XProtect only)
Enter the Milestone XProtect notification port number.
-
SSL
Select On to enable SSL connection or Off to disable SSL connection.
-
User Name
Enter the User Name for Genetec Security Center or Milestone XProtect.
-
Password
Enter your Genetec Security Center or Milestone XProtect password.
(3)
The configured VMS appears on the VMS Server screen.
(4)
Check the Alarm of AI Processing relay app in the Notification column. i-PRO Active Guard will notify VMS of AI-VMD and AI Occupancy Detection alarms.