The settings relating to the alarm action

Model[Alarm]:
WV-SW175, WV-SW174W, WV-SW172, WV-ST165, WV-ST162, WV-SC386, WV-SW396, WV-SC385, WV-SW395, WV-SC384, WV-SW355, WV-SW352

WV-NP502*, WV-NW502S*, WV-SP306*, WV-SP305*, WV-SP302*, WV-SF336*WV-SF335*, WV-SF332*, WV-SF346*, WV-SF342*

*Ver.1.40 or later


-The "Alarm Input" is detected when the terminal status is changed to "On"(Make). (Default)
-It is possible to configure the setting so that an alarm is detected when the terminal status is changed to "Off"(Open).


 

Image

 

Example

1)To change the polarity of terminal 1.
(An alarm will be detected when the terminal status is changed to "Off".)
http://IP address of the camera : + port number/cgi-bin/terminal_default?input1=nc
2)To change the polarity of terminal 1.
(An alarm will be detected when the terminal status is changed to "On".)
http://IP address of the camera : + port number/cgi-bin/terminal_default?input1=no
3)To change the polarity of terminal 2.
(An alarm will be detected when the terminal status is changed to "Off".)
http://IP address of the camera : + port number/cgi-bin/terminal_default?input2=nc
4)To change the polarity of terminal 3.
(An alarm will be detected when the terminal status is changed to "Off".)
http://IP address of the camera : + port number/cgi-bin/terminal_default?input3=nc
5)To change the polarity of terminal 1,2 and 3.
(An alarm will be detected when the terminal status is changed to "Off".)
http://IP address of the camera : + port number/cgi-bin/terminal_default?input1=nc&input2=nc&input3=nc
6)To change the polarity of terminal 1,2 and 3.
(An alarm will be detected when the terminal status is changed to "On".)(Default)
http://IP address of the camera : + port number/cgi-bin/terminal_default?input1=no&input2=no&input3=no


 Note:
-*In the judgment of the short circuit detection from the opening detection, and the open detection from the short circuit detection, the minimum required detection time is 100ms at the shortest.
-*Since there are 5 seconds not to detect once it detects, it is the shortest 5 seconds until following detection enters.
-*In the judgment of "from ON to OFF" and "from OFF to ON" to I/O terminal required is 120ms in the shortest respectively.
-*For this reason in order to detect continuation, the shortest also needs to open the interval of 240ms or more.
-*Select "Alarm input" for "Terminal alarm 1/2/3" on the [Alarm] tab.