Scenario: This page explains how to integrate VaxALPR with i-PRO Active Guard to identify and manage vehicle events through detection of license plates and attributes such as make, model, and color. By following this guide, users will be able to:

  1. Installation of VaxALPR
    1-1.Download
    1-2.Camera configuration before installation
    1-3.Installation
    1-4.Activate license
    1-5.Other configuration
    1-6.Check the detection
  2. Installation of i-PRO Active Guard
  3. Watchlist configuration
  4. Monitoring and searching watchlist events
  5. Search for license plates by plate number, MMC, etc

The integration enables the identification of three types of events:

  • Registered License Plate Detection: Identifies vehicles with license plates that are registered in the system’s watchlist.
  • Unregistered License Plate Detection: Identifies vehicles with license plates that are not registered in the system’s watchlist.
  • Registered Advanced Vehicle Detection: Identifies vehicles with specific attributes set in the watchlist (e.g., make, model, and color).

When these events occur, users can execute actions, monitor, and search watchlist events.


 

1. Installation of VaxALPR

1-1. Download

Download the application from the Download Center. To download, an account is required.

VaxALPR integration with i-PRO Active Guard for Genetec

 

Choose the application based on the type of camera SoC.

  • CV2x : VaxALRP-MMC On Camera - i-PRO CV2x
  • CV52 : VaxALRP-MMC On Camera - i-PRO CV5x

Select the area and download it.
If the camera's SoC is unknown, If the camera's SoC is unknown, refer to the following page.
Available camera resource for application

Note:

The combination requirements for the camera firmware version and VaxALPR version.

Camera SoC Camera FW Version VaxALPR Version Note
CV2x V2.60 or later V1.3.34 or later  Cameras with the CV25m SoC require RAM expansion mode to be enabled in the camera browser.
CV52 V3.20 or later V1.3.34 or later  -

*VaxALPR is pre-installed in the following models. If you want to use the latest version, please download and update it.
  WV-X15701-Z3L, WV-X15501-Z3L, WV-X15502-Z1L, WV-X15501-Z1L, WV-X15302-Z1L, WV-X15301-Z1L
 

1-2. Camera configuration before installation

  • Resolution
    To use Vaxtor's recommended resolution of 1280x720 or 1920x1080, set the resolution to either JPEG or Stream in the camera firmware settings. Make sure to configure this resolution setting before installing the Vaxtor app.
  • (CV25m camera only) RAM capacity expansion mode
    For "RAM capacity expansion mode," select "On" and then click "Set."
VaxALPR integration with i-PRO Active Guard for Genetec

 

1-3. Installation

Check the "Install new Ext. software", click the "Choose File", select the downloaded application, and then click the "Execute".

VaxALPR integration with i-PRO Active Guard for Genetec

 

1-4. Activate license

For pre-installed models, you can use a 30-day trial license by selecting "Activate trial license". Only online activation is available, so please check network configuration in advance. If you have a product key, clicking the "Show licensing options" button will display the same license screen as other models.

VaxALPR integration with i-PRO Active Guard for Genetec

 

To activate using product key, contact i-PRO regional representative to purchase a software license. You will be sent a Product Key which looks something like: a13c5eb4-a962-406c-99e0-93f8fdfd9ae7. 

VaxALPR integration with i-PRO Active Guard for Genetec

 

Licenses can be redeemed in 2 ways: 

  1. Online (Camera must have access to https://licensing.vaxtor.com) 
    Type or copy in the provided Product Key and select the Disk icon to submit the Product Key
     
  2. Offline
    Select Get C2V. This saves a c2v file to your computer’s Download Directory. 
    Upload and generate the V2C at https://licensing.vaxtor.com using your product key to login 
    Select Upload V2C and browse to the V2C file to upload it

 

1-5. Other configuration

Set the countries in [Setting].
Enable "Extended Analytics" to use vehicles brand, model, class and color information on Active Guard.

VaxALPR integration with i-PRO Active Guard for Genetec

 

Ensure that the resolution is set to 1920x1080 or 1280x720 (Vaxtor's recommended resolution).

VaxALPR integration with i-PRO Active Guard for Genetec

 

To work with Active Guard, check "Active" and select "i-PRO Active Guard" for the "Destination" on [Reports] - [ONVIF].

VaxALPR integration with i-PRO Active Guard for Genetec

 

1-6. Check the detection

The most recent plate reads are stored in the camera’s internal memory and can be viewed by selecting the Plates menu.

VaxALPR integration with i-PRO Active Guard for Genetec

 

 

2. Installation of i-PRO Active Guard

Refer to the "Genetec" - "1. i-PRO Active Guard" manual on the following page to perform the installation.
Useful links for i-PRO Active Guard system configuration | i-PRO Products

You can also download the software from this page.

  • i-PRO Active Guard Plug-in for Genetec
  • i-PRO Active Guard Server Software for VMS

For new installation of i-PRO Active Guard server, required configuration will be done by installer.
For adding new camera or app on existing Active Guard server,  refer to the manual, "Register Cameras".
 

3. Watchlist configuration

3-1. Creating a Watch List

Select [Security Desk] - [Task] - [i-PRO Active Guard Search].

VaxALPR integration with i-PRO Active Guard for Genetec

 

Select "Setup watchlists".

VaxALPR integration with i-PRO Active Guard for Genetec

 


Choose [LPR].
Click "Manage license plate" in the top right corner.

VaxALPR integration with i-PRO Active Guard for Genetec

 

Click "Manage groups".

VaxALPR integration with i-PRO Active Guard for Genetec

 

Enter the group name and click "Add" button.
Click "Save group" button, then click "×" button in the top right corner to close.

VaxALPR integration with i-PRO Active Guard for Genetec

 

Click "New license plate".

VaxALPR integration with i-PRO Active Guard  for Genetec

 

Enter the license plate, select the group and country, then click "Save" button.
Click "×" button in the top right corner to close.

VaxALPR integration with i-PRO Active Guard  for Genetec

 

Click "×" button in the top right corner to close.

VaxALPR integration with i-PRO Active Guard for Genetec

 

Click "Create New watchlists".
Disable "Detect by vehicle appearance only".
In the group section, select the group you created earlier.
Under Trigger, choose "When license plate in the selected group is detected".
Click "Save watchlist", then click "×" button in the top right corner to close.

Note: If you want to "detect license plates that are not registered", select "When other license plate which is not in the selected group is detected" under Trigger.
 

VaxALPR integration with i-PRO Active Guard  for Genetec

 

When using "Registered Advanced Vehicle Detection," enable "Detect by vehicle appearance only" and select conditions such as "Vehicle type", "Vehicle color", and "Vehicle brand".

VaxALPR integration with i-PRO Active Guard for Genetec

 

3-2.Action setting
Select [Config Tool] - [System] - [General settings] - [Actions].
Click “+” button.

VaxALPR integration with i-PRO Active Guard for Genetec

 

In the "When" field, select the target event based on the trigger you chose when creating the watchlist.
Choose the action you want to perform when the event occurs in Action; for example, select "Play sound".
Click "Save" button.

Events in "When" field Trigger in watchlist 
Registered License plate Detection (i-PRO) When license plate which is not in the selected group was detected
Unegistered License plate Detection (i-PRO) When other license plate which is not in the selected group was detected
Registered Advanced Vehicle Detection (i-PRO) Detect by vehicle appearance only

 

VaxALPR integration with i-PRO Active Guard for Genetec

 

4 Monitoring and searching watchlist events

4-1. Monitoring watchlist events
Select [Security Desk] - [Tasks] - [Monitoring].
Click "Monitoring" in the bottom left menu. Click "+" button to add the target camera.
When a registered license plate is detected, it will display "Registered License Plate Detection (i-PRO)" and the camera feed will be shown.

Note: If you created a watchlist with "When other license plate which is not in the selected group was detected", it will display "Unregistered License Plate Detection (i-PRO)".

VaxALPR integration with i-PRO Active Guard for Genetec


4-2. Searching watchlist events
Select [Security Desk] - [Tasks] - [i-PRO Active Guard Event].
Select conditions such as "Entities", "Event", "Time range", and click "Generate report" to display the reports. In LPR, filtering is possible using the created watchlists. A list of events that match the conditions will be displayed.

VaxALPR integration with i-PRO Active Guard  for Genetec

 

5. Search for license plates by plate number, MMC, etc

5-1. Select [Security Desk] - [Tasks] - [i-PRO Active Guard Search].

Search LPR for Genetec

 

5-2. Select the date, camera, and LPR filter options, then click Search.

LPR Search for Genetec

 

The filter options are as follows

Features and controls Description
License plate Secify a License plate number.
Note:
 Use '%' for wild card search
(Example : for plates starting with 'A', enter 'A%'
Country Specify the country or ADR
State *1 Specify the state
Moving Direction Towards/in, Away/out, Stopped
Type Car, Van, Mini-Van, SUV, Truck, Bus, Pickup Truch, Motercycle 
Color Black, Gray, White, Beige, Brown, Orange, Golden, Yellow, Green, Blue, Purple, Red
Brand Specify the brand
Model *2 Specify the model
Additonal filters Color image only
Note:
Black & white images may show in the search results even if only Color image only is specified.

*1 : State is displayed when Country is set to "United States" or "Australia"
*2 : Model is displayed after setting Brand.

 

5-3. The search results matching the criteria will be displayed in a list.

LPR Search for Genetec

 

5-4. You can play it by clicking on the thumbnail.

VaxALPR integration with i-PRO Active Guard for Genetec

 

5-5. Change the thumbnail display option to "Show only license plate" (Optional)

As an option, it is possible to display only the license plate as a thumbnail.
Click the gear icon in the top right corner and select "Preferences".

VaxALPR integration with i-PRO Active Guard for Genetec

 

Choose "Show only license plate" and click "Save."

VaxALPR integration with i-PRO Active Guard for Genetec

 

The search results will display thumbnails showing only the license plates.

VaxALPR integration with i-PRO Active Guard for Genetec

 

 

 

Genetec Security Center 5.12 / Driver Pack 12.5