Input alarm for Milestone

Last update: Sep, 2024

Input alarm(Terminal alarm) setting to Milestone Xprotect.


<Milestone setting>

1. Enable "Input 1". when registering the camera.
Refer to the camera registration page for details on camera registration.

Input alarm for Milestone

 

2. Select the target device and select "Input1". Select [Event]  and click "Add" .
Select "Input Rising event" and click "OK".
Click save.

Input alarm for Milestone

 

3. Setup [Rules and Events].
This step is the same as a step in the AI-VMD process. Please refer to the AI-VMD page from steps 4 to 13.
In this step, select "Device" - "Input Activated" as the Event.
 

Input alarm for Milestone

 

4. Select [Alarm] - [Alarm Definition].
Right-click on "Alarm definitions" and select "Add New" to create one.
Select the following item in the Trigger field and save.

・Triggering event:"System Events" - "Input Activated" 
・Sources:Select the target camera or "All input"

Input alarm for Milestone

 

<Comfirmation of XProtect  Smart Client>

1. After the alarm occurs, check the Alarm Manager tab in Xprotect Smart Client.
The message field will display "Input Activated"

Input alarm for Milestone

 

 

Milestone XProtect Management Client 2024 R1 /DP 13.2a