ASM300

WV-ASM300 i-PRO

i-PRO Management Software

Video Surveillance Software

• Connect up to 100 network video recorders (NVRs) and digital video recorders (DVRs).

• 64 encoders, and 256 directly connected cameras.

• Up to 12,800 cameras registered in the recorders and 256 cameras registered in the encoders are automatically
indexed in the software.

• Supports 16:9, 4:3 and 9:16 corridor format aspect ratio video streams to be displayed on the same monitor.

• All LIVE, MAP, and OPERATION monitors support 4K resolution for demanding high-resolution operation.

• With the combination using i-PRO Extreme cameras and recorders provide full end-to-end AES-256bit encryption system with for mission critical applications.

• Camera SD card full-encryption-video-recording on the edge can be quickly downloaded and decrypted under a secured environment.

FULLY INTEGRATED
• Integrated camera control, viewing and recorder management
• Integrates i-PRO Extreme H.265 & i-PRO H.264 equipment

POWERFUL USER INTERFACE
• NEW user-interface design & 4K native GUI enhances usability
• Automatic camera configuration wizard speeds system set-up
• WV-ASM300 now includes multi-monitor and WV-CU950 support as standard

EASY TRIAL OPTIONS
• No camera channel license nor annual fees required

EXTREME DATA SECURITY
• Support i-PRO“AES-256bit” encryption video
* The following functions are not available when secure communication is enabled.
- Heat map display function
- Camera setup panel function
- SD memory download (FTP) function


SCALABLE AND EXTENDABLE
• Base : 100 recorders, 64 encoders and 256 cameras
• Expandable to thousands of cameras, recorders and encoders
• Full array of software extension modules available

Specifications

Data Sheet

A&E Spec Sheet

Manuals

User Manual/Operating Instruction

WV-ASM300 Operating Instructions (English)

WV-ASM300 Operating Instructions (English)

- This manual includes Installation Guide.
- The file is converted from the help file included in the product. It is an unofficial manual and the file is not included in the product.

WV-ASM300 Operating Instructions - Help file (English)

WV-ASM300 Operating Instructions - Help file (English)

- This manual includes Installation Guide.

Firmware/Software

Software

WV-ASM200, ASM300 how to register the options for the product in use

WV-ASM200, ASM300 how to register the options for the product in use

To customers using the optional extension for video analytics
WV-ASM300 DB Convert tool

WV-ASM300 DB Convert tool

This tool is for upgrading from WV-ASM200 to WV-ASM300 including the setup file conversion.

How to upgrade from WV-ASM200 to WV-ASM300 : Upgrade_Procedure.pdf (Click here for download)

WV-ASM300 Software

WV-ASM300 Software

Version 7.31
• Trial (DEMO / LITE) (Click here for detail)
Note:

To users of WV-ASM300 DEMO Ver 1.00, please upgrade to the latest version.
Otherwise, the trial period for WV-ASM300 might expire before 90 days and unable to use if your PC has once used the demo version of the WV-ASM200 series.


• Regular
[Important notice before upgrading this software]

Please make sure to save a backup of setup data before upgrading this software to avoid losing the following settings:
(1) Basic setup: Language, Date format, Time frmat
(2) Drawing setup: Contrast enhanced display (RGB:0-256), Audio
(3) GUI display setup: Full screen display when opening the operation window
(4) Performance setup: HD300 (Live)

[Important notice on 3D dewarp fucntion]
Try the followings when the image does not appear properly after enabling 3D dewarp:
- Update the driver of the built-in video card to the latest version
- Connect the display for the operation monitor to an external video card.
(For details, refer to Graphics accelerator in the "System requirements" section of the instruction manual)
 

[Important notice for users of version1.20 or earlier]

Please upgrade WV-ASM300 version 1.21 (or later) before upgrading OS from the older versions to Windows 10 on your PC, or Windows Update on Windows 10 is applied. Otherwise, the license information of WV-ASM300 might be cleared on a PC when it is upgraded.
For your reference, if the license registration window appears when you start WV-ASM300, please register the same license information again on the registration window.

[Important notice before upgrading to V3.10 or later]
The function below will be supported by facial recognition server WV-ASF950 in V3.00 or later:
- Search by category function added to [Alarm search] tab in WV-ASM300 V3.10 or later
 

--- Video analytics function ---

The video analytics function to be activated by "Registration key"issuedby Key Management System.
 
"Registration Key" issue
"Activation Key No.", "Registration ID" and "MPRID"will be required to issue "Registration Key".
 
Activation Key No.: 0405-0065-000B-1234
Registration ID: 25D5-7547
MPR ID: Please refer to "MPR ID" displayed on your ASM300.
 
Please access to the following URL "Key Management System" andissue Registration Key . 
For mobile: https://kms-business.i-pro.com/ipkms/m-key/ ("RegistrationKey issue only")
 
* It is available this license key only customers who purchased formally WV-ASM300.
* Refer to "To customers using the optional extension for video analytics (PDF)" how to register the options for the product in use.
 
WV-ASM300 Software (Chinese)

WV-ASM300 Software (Chinese)

Version 7.10
• Trial (DEMO / LITE) (Click here for detail)
Note:

To users of WV-ASM300 DEMO Ver 1.00, please upgrade to the latest version.
Otherwise, the trial period for WV-ASM300 might expire before 90 days and unable to use if your PC has once used the demo version of the WV-ASM200 series.


• Regular
[Important notice before upgrading this software]

Please make sure to save a backup of setup data before upgrading this software to avoid losing the following settings:
(1) Basic setup: Language, Date format, Time frmat
(2) Drawing setup: Contrast enhanced display (RGB:0-256), Audio
(3) GUI display setup: Full screen display when opening the operation window
(4) Performance setup: HD300 (Live)

[Important notice on 3D dewarp fucntion]
Try the followings when the image does not appear properly after enabling 3D dewarp:
- Update the driver of the built-in video card to the latest version
- Connect the display for the operation monitor to an external video card.
(For details, refer to Graphics accelerator in the System requirements section of the instruction manual)
 

[Important notice for users of version1.20 or earlier]

Please upgrade WV-ASM300 version 1.21 (or later) before upgrading OS from the older versions to Windows 10 on your PC, or Windows Update on Windows 10 is applied. Otherwise, the license information of WV-ASM300 might be cleared on a PC when it is upgraded.
For your reference, if the license registration window appears when you start WV-ASM300, please register the same license information again on the registration window.

[Important notice before upgrading to V3.10 or later]
The function below will be supported by facial recognition server WV-ASF950 in V3.00 or later: 
- Search by category function added to [Alarm search] tab in WV-ASM300 V3.10 or later
 

--- Video analytics function ---

The video analytics function to be activated by "Registration key"issuedby Key Management System.
 
"Registration Key" issue
"Activation Key No.", "Registration ID" and "MPRID"will be required to issue "Registration Key".
 
Activation Key No.: 0405-0065-000B-1234
Registration ID: 25D5-7547
MPR ID: Please refer to "MPR ID" displayed on your ASM300.
 
Please access to the following URL "Key Management System" andissue Registration Key . 
For mobile: https://kms-business.i-pro.com/ipkms/m-key/ ("RegistrationKey issue only")
 
* It is available this license key only customers who purchased formally WV-ASM300.
* Refer to "To customers using the optional extension for video analytics " how to register the options for the product in use.

Release Note

WV-ASM300 Version history

WV-ASM300 Version history

Product: WV-ASM300

Other

Technical Document

WV-ASM300 Trial License Relationship

WV-ASM300 Trial License Relationship

Note: To users of WV-ASM300 DEMO Ver 1.00, please upgrade to the latest version. Otherwise, the trial period for WV-ASM300 might expire before 90 days and unable to use if your PC has once used the demo version of the WV-ASM200 series.

Close