Tailgating Detection by AI-VMD Cross Line
Last updated: August 2025
Scenario:
With AI-VMD version 3.80 or later, AI-VMD Cross Line supports tailgating detection.
This page explains how to configure Milestone XProtect to receive AI-VMD Cross Line events and notify alarms for tailgating.
1. Camera Settings
2. Milestone Settings
2.1 Event Settings
2.2 Create Alarm
2.3 Alarm List Configuration
3. How It Works
AI-VMD for Tailgating Detection:
For more details, refer to the following pages.
AI-VMD version 3.80 Release Note
How to Set Up Tailgating Detection with i-PRO AI-VMD|Secure Your Entrances
1. Camera Settings
1. Open the camera settings screen and go to [-Ext. software] > [AI-VMD].
2. Go to [2. AI motion detection setting].
3. Select [Cross line] in the [Detection mode] setting.
Draw the cross line boundary.
Click [Set].
4. Go to [4. Detailed setting].
5. Select the desired time in [Tailgating detection time] setting.
Click [Set].
2. Milestone Settings
Configure events and alarms in the Management Client to receive alarms.
2.1 Event Settings
1. Open [Management Client].
2. Go to [Servers] > [Recording Servers].
3. Select the target camera device and click the [Events] tab.
4. Click [Add...].
5. Select [CrossLine Human], and click [OK].
6. Enter the Detection area ID added from step 3 of Section 1 into the [Motion Window] of the event. If the Detection area ID is 1, set 1 in the Motion Window.
7. Click the [Save] icon at the top left of the screen.
2.2 Create Alarm
1. Go to [Alarm] > [Alarm Definitions] in the [Site Navigation] area.
2. Then right click [Alarm Definitions] in the [Alarm Definitions] area and select [Add New...].
3. Set the following settings. [Name] setting is shown in the [Alarm] column of the [Alarm Manager] tab in the [XProtect Smart Client].
Enable:Check the checkbox
Name:Tailgating
Triggering event(The first drop-down):Device Events
Triggering event(The second drop-down):CrossLine Human
Sources:Select the target camera
4. Click the [Save] icon at the top left of the screen.
2.3 Alarm List Configuration
1. Go to [Alarms] > [Alarm Data Settings] > [Alarm List Configuration].
2. Add [Alarm] to [Selected columns].
3. Click the [Save] icon at the top left of the screen.
3. How It Works
1. Open [Smart Client] and go to [Alarm Manager].
2. Right-click the column header in the list, and check [Alarm].
3. When an AI-VMD Cross Line event occurs, a notification for tailgating appears in the [Alarm Manager].