WV-S4176 series
Update on January 30, 2025
i-PRO Co., Ltd.
Download Firmware: WV-S4176 series firmware
Applicable model list
WV-S4176 , WV-S4576L , WV-S4576LM , WV-S4156 , WV-S4556L , WV-S4556LM , WV-S4156A , WV-S4556LA , WV-S4556LMA , WV-S4176A , WV-S4576LA , WV-S4576LMA
Priority Rank Level:
🅰︎: Recommended to apply
🅱: When issue happened
🅲: Maintenance timing
Released Versions:
V2.80 | V2.70 or earlier
Version 2.80
Release date: January 30, 2025
New Features / Improvements
- Support PKCS#12 for HTTPS.
- Added Host name setting to [Network settings].
- Added a link of [Detailed setting] to the screen for tablet terminals.
- Support “+” symbol in [Remote Monitoring registration mail address].
- Improved the connectivity to Video Management Software (VMS).
- Improved ONVIF connection.
- Improved the response to the following CGI commands.
- /cgi-bin/getdata - Optimize memory usage when using AI-VMD.
Resolved Issues
Corrected the following issues including other minor issue:
- Corrected an issue where image streaming to a specific 3rd party media player might stop. 🅲
- Improved the user interface. 🅲
- Corrected an issue where [Image capture mode] could not be changed from "Fisheye" to "Quad streams" on the live window. 🅲
- Corrected an issue where the [Image capture size] of JPEG(2) was configurable even when AI Privacy Guard is working. 🅲
*JPEG(2) cannot be used when AI Privacy Guard is on. - Corrected an issue where the VMD area window did not open showing a blue screen instead. 🅲
Occurrence condition: After moving to "TCP alarm notification" setting from the VMS area window. - Corrected an issue where the image appeared distorted. 🅲
Occurrence condition:
- [Image capture mode] is set to "Fisheye + Double Panorama", "Fisheye + Panorama" or "Fisheye + Quad PTZ"
- Select 640x640 for image capture size of multi-screen - Corrected an issue where the Command alarm pop-up did not appear on the live window when [Alarm test] is executed. 🅲
Occurrence condition: When Command alarm is turned off. - Corrected an issue where HTTPS connection might not be possible after re-installing a CA certificate. 🅲
- Corrected an issue where the setting window did not open showing a blue screen instead. 🅲
Applies to: VMD area/ SCD area/ Audio detection/ Impact detection/ Casing open detection windows
Occurrence condition: When the web browser is closed while displaying the setting window - Corrected an issue where registered preset positions might not be selectable on the live window, depending on the version of web browser. 🅲
- Corrected an issue where a black line might appear on the image on rare occasion. 🅲
Occurrence condition:
- When the camera is started
- When the mode is switched from black and white to color