  6. TCP Alarm Configuration in an Environment with Multiple Archivers for Genetec

 Troubleshooting: TCP Alarm Configuration in an Environment with Multiple Archivers

Last updated: February 2026

 

Scenario: If multiple Archivers are configured on the same PC, TCP Notification port conflicts may occur, which can prevent alarms from being received correctly. To ensure proper alarm reception, please verify that an unique TCP Notification port is assigned to each Archiver.

1. Check the Genetec Settings
2. Check the Camera Settings

 

Use case which requires careful configuration:

 

When running multiple Archivers on the same system (PC), careful configuration is required.
Multiple Archivers cannot use the same port (e.g., 1818) simultaneously on a system (PC).
If there is only one Archiver on a system (PC), there is no problem.


Additional Notes (When using failover):
When using failover, this careful configuration is required because the active Archiver also function as a failover.
The second Archiver used for failover (and the third one, if applicable) must use an unique TCP Notification port.
 

 


1. Check the Genetec Settings 

1.1 Check the TCP Notification Port

1. Select [Archiver] in [Config Tool] > [Video] > [Roles and units].

 

2. Open the [Extensions] tab and select [i-PRO/Panasonic] in [Installed extensions].

3. Ensure that the [TCP Notification port] under [Notifications] does not conflict with the port number used by other Archivers.(Default: 1818)

 

4. Repeat steps 1 through 3 for each Archiver.

For example:

Archiver1: 1818

 

 Archiver2: 1819

 

 

2. Check the Camera Settings

2.1 Check the TCP Notification Port

When the [TCP Notification port] is changed in Step 1, the registered cameras will reconnect and update the port number.

Verify that the destination port on the camera side matches the Archiver’s [TCP Notification port] configured in Step 1.

1. Open the [Notification] in [Setup]>[Alarm].

2. Check the [Destination port].

 For example:

Archiver1: 1818

 

 Archiver2: 1819

 

 


Security Center V5.13.3.0 with Driver Pack 13.4