WV-X15700-V2L series

Update on February 9, 2026
i-PRO Co., Ltd.

Download Firmware: WV-X15700-V2L series firmware

 

Applicable model list (4K/6MP/5MP/2MP model)

4K model: WV-X25700-V2LN, WV-X22700-V2L, WV-X15700-V2LN, WV-X15700-V2L
6MP model: WV-X25600-V2LN, WV-X22600-V2L, WV-X15600-V2LN, WV-X15600-V2L
5MP model: WV-X25500-V3LN, WV-X22500-V3L, WV-X15500-V3LN, WV-X15500-V3L
2MP model: WV-X25300-V3LN, WV-X22300-V3L, WV-X15300-V3LN, WV-X15300-V3L


Priority Rank Level:   
 🅰︎: Recommended to apply
 🅱: When issue happened
 🅲: Maintenance timing

Released Versions:
V3.67 | V3.65 | V3.60 | V3.50 | V3.45 | V3.41 | V3.40 | V3.30 or earlier


 

Version 3.67

Release date: February 9, 2026

Resolved Issues 

  • Corrected an issue where extension software could not be installed under specific conditions. 🅲
    Occurrence conditions: When all of the following conditions are met:
    -When using Remote Monitoring.
    -Camera firmware version is V3.65.
  • Corrected an issue where extension software could not be configured or upgraded under specific conditions. 🅲
    Occurrence conditions: When all of the following conditions are met:
    -When using Remote Monitoring (for camera direct connection).
    -Camera firmware version is V3.65.

 

Version 3.65 

Release date: December 22, 2025

New Features / Improvements 

  • Improved the [Alarm test] function for HTTP alarm notifications so that users can specify the destination of trap as well as the trap content.
  • Support HTTPS and 802.1X certificates with expiration dates beyond the year 2050.
  • Improved ONVIF connection.
  • Enhanced security.

Resolved Issues 

  • Corrected an issue where images were not displayed at equal intervals during H.264 streaming. 🅲
    Occurrence conditions: When streaming with H.264 at a low frame rate.
  • Corrected an issue where the image sensor was occasionally reset, causing a short distortion in the image. 🅲
    Occurrence conditions: When the camera experienced a high processing load.
  • Corrected an issue where communication with the camera could occasionally fail after a reboot. 🅲
    Occurrence conditions: When the camera performed a self-reboot to recover from an internal error.
  • Corrected an issue where 802.1X connection failures occurred. 🅲
    Occurrence conditions: When using 802.1X and the server certificate size exceeds 6KB.
  • Corrected an issue where incorrect log messages were displayed. [Previous log: ROM capacity limit/Updated log: Communication error] 🅲
    Occurrence conditions: When extension software installation failed due to network communication issues.
  • Corrected an issue where recorded images on the SD memory card could not be played back. 🅲
    Occurrence conditions: When recording to an SD memory card with a short refresh interval and low bitrate settings.
  • Corrected an issue with the following CGI command. 🅲
     - /cgi-bin/setdata
     - /cgi-bin/set_h264, set_h264_2
  • Corrected an issue where focus could become blurred after camera reboot under specific conditions. 🅲
    Occurrence conditions: When all of the following conditions are met:
     -The temperature difference between the time focus was set and the reboot exceeds 35°C
     -The camera is operating in black and white images mode during reboot
     -The frame rate is set to 15 fps during reboot
  • Corrected an issue where the camera occasionally restarted after long-term continuous operation. 🅲
    Occurrence conditions:When all of the following conditions are met:
     -When AI-VMD was uninstalled.
     -Camera firmware version is V3.50 or V3.60
  • Corrected an issue where IR LED brightness occasionally became unstable. 🅲
    Occurrence conditions: When shooting a nearby subject in an IR-LED environment.

 

Version 3.60 

Release date: September 30, 2025

New Features / Improvements 

  • Improved a function to notify an alarm if the SD memory card is removed during operation.
  • Support extension software installation/upgrade via Remote Monitoring.
  • Support AI On-site Learning settings via Remote Monitoring.
  • Corrected the notification source information of the alarms in the app applied to cameras 2 to 4 to be the information for each camera, when working with AI Processing Relay.
  • Enhanced security.

Resolved Issues 

  • Corrected an issue where detection frame information of AI Occupancy Detection was not included in the recorded video on an SD memory card. 🅲
    Occurrence conditions: When [Audio recording] is set to "On" on the [SD memory card] setting.
  • Corrected an issue where alarms from Cam1 were not transmitted to the Genetec Security Center. 🅲
    Occurrence conditions: When using AI Processing Relay

 

Version 3.50 

Release date: September 30, 2025

New Features / Improvements 

  • OSS update.
  • Enhanced security.

Resolved Issues 

  • Corrected an issue where operations in web browser is impossible because the authentication windows displays repeatedly. 🅲
    Occurrence conditions(example) : When a user with the "Camera Control" of access level operates the "Brightness".

 

Version 3.45 

Release date: May 30, 2025

New Features / Improvements 

  • Added [Detailed setting] to [HTTP alarm notification] settings.[More details(*1)>>]
  • Added [Mic input] and [Audio output] buttons to the top of the live image page.
  • Improved ONVIF connection.
  • Enhanced security for handling incoming CGI commands.
    For details, refer to Security Advisories | i-PRO Products page.
    *If you are using the [Image quality setting] - [Batch change to the appropriate setting] for AI-VMD, please upgrade AI-VMD to V3.80 (or later).

 

See more details of feature improvements *1

 

*1 Detailed setting for HTTP alarm notification 

Added "Detailed setting" to the settings for [HTTP alarm notification].

[Camera May 2025] Detailed setting for HTTP alarm notification
  • HTTP request method
    Set the HTTP request method (GET/POST) for HTTP alarm notifications.
     
  • Alarm type to be linked
    Set the alarm types (Terminal/Command alarm/AI-VMD/etc.) to be linked.
     
  • Alarm Area No.
    Set the area number of the alarm to be linked.
     
  • Alarm test
    Execute the alarm test function.
     
  • Copy settings to other notifications
    Copy all settings to the selected notification destination.

 

Resolved Issues 

  • Corrected issues where authentication using EAP-PEAP (IEEE 802.1X) failed depending on the network environment. 🅲
  • Corrected an issue where SD recording for Remote Monitoring did not start, even when Remote Monitoring function was enabled with [Set recommended values] selected. 🅱
  • Corrected an issue where the focus occasionally became blurred due to static electricity or other environmental factors. 🅲

 

Version 3.41 

Release date: March 27, 2025

Resolved Issues 

  • Corrected an issue where a noise might appear on the image, on rare occasion. 🅲
    Occurrence condition:
    - 4K models
    - 30fps is selected for [Image capture mode]

 

Version 3.40 

Release date: January 30, 2025

New Features / Improvements 

  • Support PKCS#12 for HTTPS.
  • Added Host name setting to [Network settings].
  • Added a link of [Detailed setting] to the screen for tablet terminals.
  • Support “+” symbol in [Remote Monitoring registration mail address].
  • Increased the maximum RAM capacity for AI apps to 1GB.
  • Support 15fps or higher frame rate when using [Stabilizer].
    *5MP/2MP models are supported before V3.40.
  • Improved the connectivity to Video Management Software (VMS).
  • Improved ONVIF connection.
  • Optimize memory usage when using AI-VMD.

Resolved Issues 

Corrected the following issues including other minor issue:

  • Corrected an issue where image streaming to a specific 3rd party media player might stop. 🅲
  • Improved the stabilizer performance when the [Privacy zone Display type] is set to "Blurring". 🅲
    *5MP models only
  • Added an improvement for a 3rd party container application. 🅲
  • Improved the user interface. 🅲
  • Corrected an issue where the Command alarm pop-up did not appear on the live window when [Alarm test] is executed. 🅲
    Occurrence condition: When Command alarm is turned off.
  • Corrected an issue where HTTPS connection might not be possible after re-installing a CA certificate. 🅲
  • Corrected an issue where the setting window did not open showing a blue screen instead. 🅲
    Applies to: VMD area/ SCD area/ Audio detection/ Impact detection/ Casing open detection windows
    Occurrence condition: When the web browser is closed while displaying the setting window