Third-Party Application Alarm Event
Last updated: June 2025
Scenario:
With i-PRO Active Guard server v1.6.2 or later, alarm events from third-party camera applications are available. This page explains how to configure alarm events from third-party applications in i-PRO Active Guard and Video Insight:
1. i-PRO Active Guard Server Configuration
1.1 Edit Config File
1.2 Register Cameras on the i-PRO Active Guard Configuration
1.3 Restart i-PRO Active Guard Process
2. Video Insight Configuration
2.1 Rule Configuration (Optional)
3. How It Works
Compatible partner's app information:
Note: The application name and event name must be configured in Active Guard and must match exactly.
Vendor | Application name | Event name |
---|---|---|
Morpho AI Solutions | "Mimamori AI Duranta" | *configured alarm name on partner's configuration tool |
Noema | "Noema Fire and Smoke Detection iPRO App" | "Smoke detection" |
"Fire detection" | ||
Noema | "Noema Flooding Detector iPRO App" | "Flood detected" |
Third-party application:
For more details, refer to the third-party application page.
1. i-PRO Active Guard Server Configuration
1.1 Edit Config File
1. Edit [C:\MultiAI\Backup\3rdpartyApp.config] on the PC where the Active Guard server is installed.
If you have changed the installation path from the default, edit the same file located in the updated folder.

2. Enter information about each app in [application_name_x] and [event_name_x].
Note: Remove the semicolon (;) at the beginning of each line.

1.2 Register Cameras on the i-PRO Active Guard Configuration
1. Open the i-PRO Active Guard configuration in a browser at https://<ip>:8092.
2. Click [Register Cameras].
3. Select [Add devices] > [Camera(s) from VMS].

4. All i-PRO cameras, including unsupported ones, will be displayed.
Enter the camera’s credentials and click [Check].
5. Once the camera is displayed, click [Save].

1.3 Restart i-PRO Active Guard Process
1. Click [Restart].

2. Video Insight Configuration
2.1 Rule configuration (Optional)
By configuring the event name as “Category” in “Enhanced System Input”, any Actions can be used.
1. Open [Administration] - [Servers] - [Rules] - [Add Event].

2. Select [Enhanced System Input] and the select target cameras.
3. Enter the event name under [Category].

3. How It Works
1. Open [VI MonitorPlus] and select [i-PRO Active Guard Event].
2. When an alarm is triggered, the i-PRO Active Guard Event’s Live events tab displays the current event, and the Past events tab allows you to search for previous events. The configured event name will be shown in the “Extension app. event” filter.

Morpho - Mimamori AI Duranta

Noema - Fire and Smoke Detection

Video Insight 7