Phenomenon
| Cause and Countermeasure
| Reference
|
|---|
Cannot access from a web browser
| ・Are category 5e or higher cabled to the network connector?
| Instruction Manual Installation
| ・Is the link indicator (LINK) lit? If it is not lit, the LAN is not properly connected or the destination network is not working properly. Check the cable for loose connection and wiring.
| Instruction Manual Installation
| ・Check that the machine is turned on? Check that the machine is turned on.
| Instruction Manual Installation
| ・Is a valid IP addressset for this machine?
| User Manual
| ・Are you accessing the wrong IP address? Use the following procedure to check connectivity. If Reply is returned from this machine at > ping IP addressing set for the machine at Windows command prompt, the machine is operating normally. If you do not receive a Reply, check the connection in the following way on the PC connected to the same network as the camera. If the PC firewall setting is enabled, temporarily cancel the setting and then perform thecamera setting. ・ Start the IP Quick Setup software. Check the IP address of the camera. Then, access the IP address. ・ If the network settings (IP address, subnet mask, default gateway) are incorrect, restart thecamera and change the network settings using the IP Easy Setup software within 20 minutes. ・ If initialization is performed by restarting the unit without a DHCP server, the IP is set to [192.168.0.10]. Then, re-set the IP address by accessing the machine (at this time, all machine settings are initialized).
| -
| ・Have you set 554 to the HTTP port number? Use a port number other than 20, 21, 22, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443,554, 995, 1883, 8883, 10669, 10670, 59000 to 61000 as the HTTP port number to use with this unit.
| User Manual
| ・Is the set IP address duplicated with other devices? Is the set address inconsistent with the destination network/subnet? [When the instrument and PC are connected in the same subnet] Is the IP address of the instrument and PC set in the same subnet? Also, is [Use Proxy Server] set in the PC? When accessing this machine in the same subnet, it is recommended to set the address of this machine to [Remove from Proxy] address. [When this machine and the PC are connected to different subnets] Is the default gateway set for this machine incorrect?
| -
| ・When using the HTTPS function, if you are using the [http://] to access? HTTPS, use the [https://] to access. You also need to enter the port number. From the support video page of the support site<Control No. :P0002>、<Control No. :P0003>See also.
| -
|
|