[Terminal 1] Sets the operation of terminal 1.
・[Off]: Pin functions are not used.
・[Alarm input(TRM1)]: Accepts terminal alarm input.
・[Close]: Alarm is detected when the pin status changes to [Close].
・[Open]: Alarm is detected when the pin status changes to [Open].
・[Close(Continue)]: Alarm is detected when the pin status changes to [Close]. When the pin status is [Close], the alarm is detected periodically at the alarm non-detection interval.
・[Open(Continue)]: Alarm is detected when the pin status changes to [Open]. When the pin status is [Open], the alarm is detected periodically at the alarm non-detection interval.
・[Radar]: Operates as radar alarm input.
・[Cameras]: Operates as an alarm input for the camera.
・[Radar Self check Start]:You can check whether the radar is operating normally.
・[Close]: Radar self-test starts when the pin status changes to [Close].
・[Open]: Radar self-test starts when the pin status changes to [Open].
・[Black & white input]: Accepts black and white switching input. (Switches to black and white when the entry is [On].)
・[Auto time adjustment]: Accepts the time setting by terminal input. If the time difference from the hour (every hour 00 minutes) is within 29 minutes, set to 00 minutes 00 seconds. If the time is less than 5 seconds during SD recording, the time is not changed. When "AUTO TIME ADJUST" is selected, the short-circuit and open selection pull-down menus are displayed.
・[Close]: When the pin status changes to [Close], the watch automatically adjusts the time.
・[Open]: When the pin status changes to [Open], the watch automatically adjusts the time.
|