1. 2. 3. 4. If you want to set the i-VMD detection sensitivity, detection duration, and size of the human you want to detect: Make detailed settings →3.4 Detailed setting (if necessary) 5. 6. |
|
![]() |
|
| ||||
![]() |
|
|
|
![]() a: alarm notification area, b: drawing area, and c: detection condition setting |
|
![]() |
1 Alarm ICON 2 CROSS LINE 3 INTRUDER 4 LOITERING 5 DIRECTION |
![]() a: camera image screen, b: Paint type |
|
|
![]() |
1. Cross line (Setting): Draws detection lines for CROSS LINE. 2. Detection area (Setting): Draws Detection area as a polygon (up to 16 sides). 3. Mask Area (Setting): Draws the mask area as a polygon (up to 16 sides). 4. Detection area (Select): Select the drawn Detection area. 5. Mask Area (Select): Select the drawn mask area. 6. Delete: Deletes the selected Detection area (line) and mask areas. 7. All Delete: Deletes all drawn Detection area (line) and mask areas. |
| ||||
|
| ||||
|
|
INTRUDER: Detects that moving bodies have intruded the detection area. LOITERING: Detects that moving bodies have loitered in the detection area for the fixed time. DIRECTION: Detects that moving bodies have moved in the direction you specified within the detection area. CROSS LINE: Detects that moving bodies have crossed the detection line in the direction you specified. |
|
|
Upper: Detected when moving upward. Upper right: Detected when moving in the upper right direction. Right: Detected when moving in the right direction. Lower right: Detected when moving in the lower right direction. Lower: Detected when moving downward. Lower left: Detected when moving in the lower left direction. Left: Detected when moving to the left. Upper left: Detected when moving in the upper left direction. |
|
A→B: Detected when moving from A to B. B→A: Detected when moving from B to A. A⇔B: Detected when moving from A to B or from B to A. |
|
|
1. Make sure the [Area Setting] screen is selected. 2. Ensure that the [Detection program 1] tabs are selected. 3. Draw an area for detection (hereinafter referred to as "Detection area") in the drawing area. Draw a location (hereinafter referred to as the mask area) that you do not want to detect in the Detection area. Eight Detection area and eight mask armatures can be set respectively. 4. Configure four Detection mode for each Detection area: INTRUDER, LOITERING, DIRECTION and CROSS LINE, respectively. 5. If Detection mode is [DIRECTION] or [CROSS LINE], configure [Direction setup]. 6. Save the [Detection program 1] detection condition by clicking [Setup]. 7. Select the [Detection program 2] tabs and save the [Detection program 2] detection criteria in steps (3) to (6). |
|
![]() |
|
|
|
|
|
| ||||
|
| ||||
|
|
|
| ||||
![]() |
|
|
![]() Example of Depth Setting |
| ||||
|
|
|
| ||||
|
|
Off: i-VMD does not add data. Also, the detection frame and Locus are not displayed. On: Adds i-VMD data, but does not display detection frame or Locus. On(with live display): On(with live display [with blue frame]): |
|
|
![]() |
|
![]() |
|
|
|
|
|
|
|
|
|
|