(1) Configure settings for non-AI cameras. |
|
|
|
| ||||
(2) Displays the configuration screen for iCT's extension software. |
![]() |
① Start iCT and click on "Ext. Software Management" in the menu on the left side. ② Click "Configure AI Processing Relay". ③ Check the cameras for which you want to install the extension software from the device list. ④ Click "Setting/Confirmation". |
(3) Configure AI Processing Relay settings. cam2, cam3, and cma4 are supported by AI Processing Relay Cam2, AI Processing Relay Cam3, and AI Processing Relay Cam4. |
![]() |
① Select [i-PRO Camera] from [Target Camera]. ② Drag and drop the camera to be set for AI Processing Relay Camera 2, 3, or 4. The figure shows AI Processing Relay Camera 2 set with an i-PRO camera. ③ The information obtained by iCT is automatically reflected in the fields for AI Processing Relay Camera 2, 3, and 4. Adjust the settings according to your environment. The information obtained through iCT is automatically configured. |
- [IP address] Enter the IP address assigned to the non-AI camera. - [Model] Model name of the non-AI camera. - [MAC address] MAC address of non-AI camera. - [Stream URL] Enter the stream URL to retrieve the video data from the non-AI camera. If the stream URL is displayed - The stream URL obtained by iCT is displayed. The stream URL can be selected from the dropdown menu. If the stream URL is blank - Enter the command after the IP address of the camera. - Do not enter a leading “/”. The leading “/” will be automatically completed by this product. - In the case of a multi-sensor camera, please include the camera number in the command. Example: i-PRO camera (single-lens camera) cgi-bin/mjpeg?stream=1&framerate=5- [Protocol] Select the protocol to be used to access non-AI cameras from the product. - [Port No.] Enter the port number of the protocol used by the non-AI camera. - [Multi-directional cameras No.] If the non-AI camera is a multi-sensor camera, enter the camera number of the multi-sensor camera. If the non-AI camera is a monocular camera, enter 1. The information entered in this field is used when connecting to the Multi AI software. Default setting: 1 - [Username] Enter the Username that is set for the non-AI camera. - [Password] Enter the password set for the non-AI camera. |
④ Click the [Setting] button. After a while, the AI Processing Relay will receive the video using the entered [Stream URL] and display it in [Received Image(from AI Processing Relay)]. |
![]() |
|
|
| ||||
(1) Register a camera made by other company in iCT |
|
![]() |
|
|
![]() |
① Confirm that the camera from other companies is detected. If not, skip steps (1) and (2) and follow step (3). ② Enter the [username] and [password] of a camera made by other company. ③ Click the [Start] button. |
| ||||
(2) If the authentication of a camera made by other company fails, follow the steps below to authenticate the camera made by other company. |
![]() |
① Click [ONVIF Conformant Devices] tab on the iCT configuration screen ② Select the camera that failed authentication, right-click to open the submenu, and click [To resolve errors] > [Selected device only]. ③ On the next screen, set the [ Username ] and [ Password ] for the camera made by other company. |
|
| ||||
(3) Configure settings for cameras made by other company |
|
|
|
(4) Displays the configuration screen for iCT's extension software. |
![]() |
① Open iCT and click on [Ext. Software Management] in the left menu. ② Click [Configure AI Processing Relay]. ③ Check the cameras for which you want to configure extension software from the list of devices. ④ Click the [Setting/Confirmation] button. |
(5) Configure AI Processing Relay settings. cam2, cam3, and cma4 are supported by AI Processing Relay Cam2, AI Processing Relay Cam3, and AI Processing Relay Cam4. |
![]() |
① Select [ONVIF Camera] from [Target Camera]. ② Drag and drop the camera to be set for AI Processing Relay Camera 2, 3, or 4. The figure shows AI Processing Relay Camera 2 set with an i-PRO camera. ③ The information obtained by iCT is automatically reflected in the fields for AI Processing Relay Camera 2, 3, and 4. Adjust the settings according to your environment. |
- [IP address] Enter the IP address assigned to the non-AI camera. iCT automatically inputs the IP address of a non-AI camera. - [Model] Model name of the non-AI camera. If iCT is able to obtain a Model from a non-AI camera, it will be automatically populated. - [MAC address] MAC address of non-AI camera. If iCT is able to obtain the MAC address from a non-AI camera, it will be automatically populated. - [Stream URL] Enter the stream URL to retrieve the video data from the non-AI camera. If the stream URL is displayed - The stream URL obtained by iCT is displayed. The stream URL can be selected from the dropdown menu. If the stream URL is blank - Enter the command after the IP address of the camera. - Do not enter a leading “/”. The leading “/” will be automatically completed by this product. - In the case of a multi-sensor camera, please include the camera number in the command. Example: If the non-AI camera is an AXIS camera (single-lens camera) onvif-media/media.amp?profile=IPRO_MPROF_JPEG&sessiontimeout=60&streamtype=unicast- [Protocol] Select the protocol to be used to access non-AI cameras from the product. iCT will automatically populate this field if it is able to obtain the Protocol from a non-AI camera. - [Port No.] Enter the port number of the protocol used by the non-AI camera. iCT will automatically enter the port number if it is able to obtain it from the non-AI camera. - [Multi-directional cameras No.] If the non-AI camera is a multi-sensor camera, enter the camera number of the multi-sensor camera. If the non-AI camera is a monocular camera, enter 1. The information entered in this field is used when connecting to the Multi AI software. Default setting: blank - [Username] Enter the Username that is set for the non-AI camera, which will be automatically populated when the Username for the non-AI camera is entered into iCT. - [Password] Enter the password set for the non-AI camera; if you enter the password for a non-AI camera in iCT, it will be automatically entered. |
④ Click the [Setting] button. After a while, the AI Processing Relay will receive the video using the entered [Stream URL] and display it in [Received Image(from AI Processing Relay)]. |
![]() |
|
|
| ||||
1. Displays the configuration screen for iCT's extension software. |
① Start iCT and click on "Ext. Software Management" in the menu on the left side. ② Click "App. Settings". ③ Click on the tab "AI Processing Relay(Cam.2-)" at the top of the device list. ④ Check the cameras for which you want to install the extension software from the device list. ⑤ Click "Setting/Confirmation". |
![]() |
2. The detailed settings screen for the extension software will be displayed. Scroll through the menu on the left to display the extension software items. The following items are displayed in the "Ext. software" section A: Extension software for camera 1 B: Extension software for cameras 2, 3 and 4 Please refer to the manual of each extension software to set up the software. |
![]() |
|
![]() |
|
![]() |
|
| ||||
|
![]() |
| ||||
|
| ||||
1. Click "Camera Registration". |
2. Select "Add" - "AI Processing Relay App". |
![]() |
3. Enter the IP address and authentication information for the new X series camera, and click "Check". Confirm that the non-AI camera appears in the list and click "Save". |
![]() |
4. Click "Restart" to restart the i-PRO Active Guard server. |
![]() |
| ||||
|
![]() |
(1) Open Notepad and enter the following three lines. Save the file to your desktop. In this procedure, the file name will be saved as ch234_alarm.txt./cgi-bin/setdata?AIENCTCPALM_CH234=1@ time:1000/cgi-bin/getdata(2) Launch iCT, and from the left-hand menu in iCT, select [Send a CGI List]. (3) Check the camera for which you want to change the settings. (4) Configure the right-hand menu as follows and click [Start]: File Specify ch234_alarm.txt. In this procedure, the file will be:[Path to the saved folder]\ch234_alarm.txtMethod of HTTP requests GET Save the CGI response data Check this option. (5) Once the camera settings have been changed, a folder will be displayed. Inside the folder named [Camera Model][Camera IP Address][Camera Firmware Version], you will find ResponseData.txt. Confirm that the line for AIENCTCPALM_CH234 is set to 1, as shown below:AIENCTCPALM_CH234,"1" |
1. Open i-PRO Active Guard's VMS server screen and press the "Add" button. |
![]() |
2. Press the "Test" button after entering the VMS information. When "Success" is displayed, press the "Save" button. |
![]() |
- Type Select Genetec Security Center or Milestone XProtect. - IP address Enter the IP address of Genetec Security Center or Milestone XProtect. - WEB API Port Enter the port number of the Genetec Security Center or Milestone XProtect. - Notification Port (Milestone XProtect only) Enter the Milestone XProtect notification port number. - SSL Select On to enable SSL connection or Off to disable SSL connection. - User Name Enter the User Name for Genetec Security Center or Milestone XProtect. - Password Enter your Genetec Security Center or Milestone XProtect password. |
3. The configured VMS appears on the VMS Server screen. |
4. Check the Alarm of AI Processing relay app in the Notification column. i-PRO Active Guard will notify VMS of AI-VMD and AI Occupancy Detection alarms. |
![]() |