・The "Below Count Threshold" setting can be used to detect insufficient personnel in areas where at least two workers are required.
・By combining the "Above Count Threshold" and "Below Count Threshold" settings, it is possible to monitor a range of personnel counts.
■ Count Threshold and Alarm Behavior
・When the "Above Count Threshold" is set to 1
→ An alarm is triggered when there is 1 or more person (no alarm when there are 0 people).
・When the "Below Count Threshold" is set to 2
→ An alarm is triggered when there are fewer than 2 people (no alarm when there are 2 or more people).
・When the "Above Count Threshold" is set to 1 and the "Below Count Threshold" is set to 2
→ An alarm is triggered only when there is exactly 1 person (no alarm when there are 0 or 2 or more people).
・When the "Above Count Threshold" is set to 2 and the "Below Count Threshold" is set to 1
→ The condition cannot be satisfied, so no alarm is triggered.
|