2Preparation

The flow to operation is as follows. This chapter describes ① and ②.
Determine the camera installation position
2.1 Determine the camera installation position
Install the product
2.2 Install the product
Configure the required settings.
3 Setting
Start of operation
First, determine the location of the camera.
Determine the installation location according to the following conditions. Check the precautions as well.
Refer to the following pages for precautions.
1.2 Notes
Location of the camera
When considering the installation location, observe the flow line of the person to be counted and the flow line of the person passing through the area in advance.
In the case of operation as shown in Fig. B, it is recommended to install a camera near the entrance of the facility as much as possible, since the number of cases in which persons other than entrance and exit passes through the counter line increases.
Camera installation height
Height from floor: 2.0 m to 5.0 m
Camera installation position
Distance from inlet: 1.0 m or more
Camera installation
Install the screen so that the entrance can be seen in one of four directions (up, down, left, and right).
Count line setting position
Distance from camera: within recommended range
Distance from inlet : 1.0 m or more
Count line width
Length within recommended range

・The distance from the camera at the count line setting position and the recommended range of the count line width depend on the camera installation height. Refer to the following pages for details.
3.4.1 Line setting


・For the distance from the camera at the count line setting position, the closer to the center of the camera image screen (directly below the camera), the better the counting accuracy.


Download the product and install it on your camera according to the following procedures.
1.
The following URLs are accessed to download [AI-VMD/AI Count Application (for omni-directional cameras)] and store them on a PC.
Documentation Database
Do not use spaces or double-byte characters in the name of the destination directory.
2.
Select iCT submenu [Ext. Software Management] > [App. Installation/Update].
3.
Select the camera to install the application and check that the product number and [MPR ID] are displayed.
4.
Enter the following items on the setting screen.

[Extension software]: Select [AI-VMD /AI count application (for omni-directional cameras)]


[Folder] : Specify the location of the The Extension Software obtained in (1).


5.
Click [Confirm].
6.
Check that the target cameras are checked and the application versions to register/update on the confirmation window, and then click [Start].
7.
Check that the progress screen is displayed and the installation is completed successfully.