WV-U11350-V3 series
Update on February 9, 2026
i-PRO Co., Ltd.
Download Firmware: WV-U11350-V3 etc. Firmware
Applicable model list
WV-U15550-V3L, WV-U21550-V3L, WV-U11550-V3, WV-U15350-V3L, WV-U21350-V3L, WV-U11350-V3, WV-U25550-F3L , WV-U22550-F3L , WV-U25351-V3L , WV-U25350-F3L , WV-U22350-F3L, WV-U25551-V3L
Priority Rank Level:
🅰︎: Recommended to apply
🅱: When issue happened
🅲: Maintenance timing
Released Versions:
V3.67 | V3.65 | V3.60 | V3.55 | V3.52 | V3.51
Version 3.67
Release date: February 9, 2026
Resolved Issues
- Corrected an issue where extension software could not be installed under specific conditions. 🅲
Occurrence conditions: When all of the following conditions are met:
-When using Remote Monitoring.
-Camera firmware version is V3.65. - Corrected an issue where extension software could not be configured or upgraded under specific conditions. 🅲
Occurrence conditions: When all of the following conditions are met:
-When using Remote Monitoring (for camera direct connection).
-Camera firmware version is V3.65.
Version 3.65
Release date: December 22, 2025
New Features / Improvements
- Improved the [Alarm test] function for HTTP alarm notifications so that users can specify the destination of trap as well as the trap content.
- Support HTTPS and 802.1X certificates with expiration dates beyond the year 2050.
- Improved image quality under the following conditions:
-During brightness control
-In environments with IR-LED illumination - Improved ONVIF connection.
- Enhanced security.
Resolved Issues
- Corrected an issue where images were not displayed at equal intervals during H.264 streaming. 🅲
Occurrence conditions: When streaming with H.264 at a low frame rate. - Corrected an issue where the image sensor was occasionally reset, causing a short distortion in the image. 🅲
Occurrence conditions: When the camera experienced a high processing load. - Corrected an issue where communication with the camera could occasionally fail after a reboot. 🅲
Occurrence conditions: When the camera performed a self-reboot to recover from an internal error. - Corrected an issue where 802.1X connection failures occurred. 🅲
Occurrence conditions: When using 802.1X and the server certificate size exceeds 6KB. - Corrected an issue where incorrect log messages were displayed. [Previous log: ROM capacity limit/Updated log: Communication error] 🅲
Occurrence conditions: When extension software installation failed due to network communication issues. - Corrected an issue where recorded images on the SD memory card could not be played back. 🅲
Occurrence conditions: When recording to an SD memory card with a short refresh interval and low bitrate settings. - Corrected an issue with the following CGI command. 🅲
- /cgi-bin/setdata
- /cgi-bin/set_h264, set_h264_2 - Corrected an issue where focus could become blurred after camera reboot under specific conditions. 🅲
Occurrence conditions: When all of the following conditions are met:
-The temperature difference between the time focus was set and the reboot exceeds 35°C
-The camera is operating in black and white images mode during reboot
-The frame rate is set to 15 fps during reboot - Corrected an issue where the JPEG frame rate dropped to 1 fps when the [Image capture mode] was set to "4:3 (30/25 fps)". 🅲
Occurrence conditions: When changing the [Image capture mode] to "4:3 (30/25 fps) mode" under the following settings:
-Imaging mode: 16:9 (30/25 fps)
-Stream1 to 4: OFF
-JPEG resolution: 640×360
-JPEG frame rate: 30 fps
Version 3.60
Release date: September 30, 2025
New Features / Improvements
- Improved a function to notify an alarm if the SD memory card is removed during operation.
- Support extension software installation/upgrade via Remote Monitoring.
- Enhanced security.
Resolved Issues
- Corrected an issue where detection frame information of AI Occupancy Detection was not included in the recorded video on an SD memory card. 🅲
Occurrence conditions: When [Audio recording] is set to "On" on the [SD memory card] setting.
Version 3.55
Release date: September 30, 2025
New Features / Improvements
- Support D2C for Genetec Security Center SaaS.
- Added [Detailed setting] to [HTTP alarm notification] settings.[More details(*1)>>]
- Added [Mic input] and [Audio output] buttons to the top of the live image page.
- Improved ONVIF connection.
- Enhanced security for handling incoming CGI commands.
For details, refer to Security Advisories | i-PRO Products page.
*If you are using the [Image quality setting] - [Batch change to the appropriate setting] for AI-VMD, please upgrade AI-VMD to V3.80 (or later).
*1 Detailed setting for HTTP alarm notification
Added "Detailed setting" to the settings for [HTTP alarm notification].
|
|
Resolved Issues
- Corrected an issue where operations in web browser is impossible because the authentication windows displays repeatedly. 🅲
Occurrence conditions(example) : When a user with the "Camera Control" of access level operates the "Brightness". - Corrected issues where authentication using EAP-PEAP (IEEE 802.1X) failed depending on the network environment. 🅲
Version 3.52
Release date: June 27, 2025
- First mass-production for WV-U15550-V3L, WV-U15350-V3L, WV-U25351-V3L, and WV-U25551-V3L
Resolved Issues
- Corrected a minor focus issue. 🅲
Version 3.51
Release date: June 27, 2025
- First mass-production for WV-U25550-F3L, WV-U21550-V3L, WV-U11550-V3, WV-U22550-F3L, WV-U25350-F3L, WV-U21350-V3L, WV-U11350-V3 and WV-U22350-F3L