WV-S65340-Z4 series
Update on September 30, 2025
i-PRO Co., Ltd.
Download Firmware: WV-S65340-Z4 series firmware
Applicable model list
WV-S65340-Z4N , WV-S65340-Z4K , WV-S61302-Z4 , WV-S65340-Z4G , WV-S65340-Z4N1 , WV-S65340-Z4
Priority Rank Level:
🅰︎: Recommended to apply
🅱: When issue happened
🅲: Maintenance timing
Released Versions:
V3.60 | V3.50 | V2.85 | V2.80 | V2.70 or earlier
Version 3.60
Release date: September 30, 2025
New Features / Improvements
- Improved a function to notify an alarm if the SD memory card is removed during operation.
- Support extension software installation/upgrade via Remote Monitoring.
- Enhanced security.
Resolved Issues
- Corrected an issue where detection frame information of AI Occupancy Detection was not included in the recorded video on an SD memory card. 🅲
Occurrence conditions: When [Audio recording] is set to "On" on the [SD memory card] setting.
Version 3.50
Release date: September 30, 2025
New Features / Improvements
- OS update.
*After upgrading the firmware to this version or later, it is also necessary to upgrade the following extension software to V4.00 or later, if it is installed.
- AI-VMD - AI Face Detection
- AI People Detection
- AI Vehicle Detection
- AI Occupancy Detection
- AI-VMD / AI People Counting for 360-degree fisheye
- AI Scene Change Detection
- AI Processing Relay for i-PRO mini - OSS update.
- Enhanced security.
Resolved Issues
- Corrected an issue where operations in web browser is impossible because the authentication windows displays repeatedly. 🅲
Occurrence conditions(example) : When a user with the "Camera Control" of access level operates the "Brightness". - Improved communication stability under certain network conditions. 🅲
- Improved image stability during digital zoom operations. 🅲
- Improved image stability by correcting a minor issue when [Stabilizer] is turned on. 🅲
Version 2.85
Release date: May 30, 2025
->Updated on June 10: Added an item written in red
New Features / Improvements
- Support D2C for Genetec Security Center SaaS.
- Added [Detailed setting] to [HTTP alarm notification] settings.[More details(*1)>>]
- Added [Mic input] and [Audio output] buttons to the top of the live image page.
- Improved autofocus performance.
- Improved ONVIF connection.
- Enhanced security for handling incoming CGI commands.
For details, refer to Security Advisories | i-PRO Products page.
*If you are using the [Image quality setting] - [Batch change to the appropriate setting] for AI-VMD, please upgrade AI-VMD to V3.80 (or later).
See more details of feature improvements *1
*1 Detailed setting for HTTP alarm notification
Added "Detailed setting" to the settings for [HTTP alarm notification].
|
|
Resolved Issues
- Corrected issues where authentication using EAP-PEAP (IEEE 802.1X) failed depending on the network environment. 🅲
- Corrected an issue where the angle of view could shift unexpectedly after continuous manual panning in the same direction. 🅲
- Corrected an issue where SD recording for Remote Monitoring did not start, even when Remote Monitoring function was enabled with [Set recommended values] selected. 🅱
- Corrected an issue where the focus occasionally became blurred due to static electricity or other environmental factors. 🅲
Version 2.80
Release date: January 30, 2025
New Features / Improvements
- Support PKCS#12 for HTTPS.
- Added Host name setting to [Network settings].
- Added a link of [Detailed setting] to the screen for tablet terminals.
- Support “+” symbol in [Remote Monitoring registration mail address].
- Improved the Auto Focus performance.
- Improved the connectivity to Video Management Software (VMS).
- Improved ONVIF connection.
Resolved Issues
Corrected the following issues including other minor issue:
- Corrected an issue where image streaming to a specific 3rd party media player might stop. 🅲
- Improved the digital zoom performance while zooming in. 🅲
- Improved the user interface. 🅲
- Corrected an issue with the [Preset sequence setting] of the live window on Google Chrome browser. 🅲
Occurrence conditions: Display size on the PC is larger than 100%. - Corrected an issue where the Command alarm pop-up did not appear on the live window when [Alarm test] is executed. 🅲
Occurrence condition: When Command alarm is turned off. - Corrected an issue where TILT did not return to the original position(TILT=0 deg.) after a factory reset. 🅲
*This issue does not happen if the camera is rebooted after the factory reset. - Corrected an issue where HTTPS connection might not be possible after re-installing a CA certificate. 🅲
- Corrected an issue where the setting window did not open showing a blue screen instead. 🅲
Applies to: VMD area/ SCD area/ Audio detection/ Impact detection/ Casing open detection windows
Occurrence condition: When the web browser is closed while displaying the setting window - Corrected an issue where the pan control might not work after setting pan/tilt range. 🅲
- Corrected an issue where PTZ control did not work after the camera was rebooted. 🅲
Occurrence condition: When the camera is connected to Genetec VMS using ONVIF connection.