WV-S15500-V3LN series
Update on December 22, 2025
i-PRO Co., Ltd.
Download Firmware: WV-S15500-V3LN series firmware
Applicable model list
WV-S15500-V3LN , WV-S15700-V2LN , WV-S22500-V3L , WV-S22700-V2L , WV-S25500-V3LN , WV-S25700-V2LN , WV-S15600-V2LN , WV-S22600-V2L , WV-S22600-V2LG , WV-S25600-V2LN , WV-S15700-V2LK , WV-S15500-V3LK , WV-S15500-V3LN1 , WV-S22700-V2L1 , WV-S22500-V3LG , WV-S25500-V3LG , WV-S25600-V2LG , WV-S22500-V3L1 , WV-S22700-V2LG , WV-S25700-V2LG , WV-S25700-V2LN1 , WV-S25500-V3LN1 , WV-S15500-F3L , WV-S15500-F6L , WV-S22500-F3L , WV-S22500-F6L , WV-S25500-F3L , WV-S25500-F6L , WV-S15500-V3L , WV-S15600-V2L , WV-S15700-V2L , WV-S25500-V3L , WV-S25600-V2L , WV-S25700-V2L
Priority Rank Level:
🅰︎: Recommended to apply
🅱: When issue happened
🅲: Maintenance timing
Released Versions:
V3.65 | V3.60 | V3.50 | V2.85 | V2.80 | V2.70 or earlier
Version 3.65
Release date: December 22, 2025
New Features / Improvements
- Improved the [Alarm test] function for HTTP alarm notifications so that users can specify the destination of trap as well as the trap content.
- Support HTTPS and 802.1X certificates with expiration dates beyond the year 2050.
- Improved ONVIF connection.
- Enhanced security.
Resolved Issues
- Corrected an issue where images were not displayed at equal intervals during H.264 streaming. 🅲
Occurrence conditions: When streaming with H.264 at a low frame rate. - Corrected an issue where the image sensor was occasionally reset, causing a short distortion in the image. 🅲
Occurrence conditions: When the camera experienced a high processing load. - Corrected an issue where communication with the camera could occasionally fail after a reboot. 🅲
Occurrence conditions: When the camera performed a self-reboot to recover from an internal error. - Corrected an issue where 802.1X connection failures occurred. 🅲
Occurrence conditions: When using 802.1X and the server certificate size exceeds 6KB. - Corrected an issue where incorrect log messages were displayed. [Previous log: ROM capacity limit/Updated log: Communication error] 🅲
Occurrence conditions: When extension software installation failed due to network communication issues. - Corrected an issue where recorded images on the SD memory card could not be played back. 🅲
Occurrence conditions: When recording to an SD memory card with a short refresh interval and low bitrate settings. - Corrected an issue where focus could become blurred after camera reboot under specific conditions. 🅲
Occurrence conditions: When all of the following conditions are met:
-The temperature difference between the time focus was set and the reboot exceeds 35°C
-The camera is operating in black and white images mode during reboot
-The frame rate is set to 15 fps during reboot
Version 3.60
Release date: September 30, 2025
New Features / Improvements
- Improved a function to notify an alarm if the SD memory card is removed during operation.
- Support extension software installation/upgrade via Remote Monitoring.
- Support AI On-site Learning settings via Remote Monitoring.
- Corrected the notification source information of the alarms in the app applied to cameras 2 to 4 to be the information for each camera, when working with AI Processing Relay.
- Enhanced security.
Resolved Issues
- Corrected an issue where detection frame information of AI Occupancy Detection was not included in the recorded video on an SD memory card. 🅲
Occurrence conditions: When [Audio recording] is set to "On" on the [SD memory card] setting. - Corrected an issue where alarms from Cam1 were not transmitted to the Genetec Security Center. 🅲
Occurrence conditions: When using AI Processing Relay
Version 3.50
Release date: September 30, 2025
New Features / Improvements
- OSS update.
- Enhanced security.
Resolved Issues
- Corrected an issue where operations in web browser is impossible because the authentication windows displays repeatedly. 🅲
Occurrence conditions(example) : When a user with the "Camera Control" of access level operates the "Brightness".
Version 2.85
Release date: May 30, 2025
->Updated on June 10: Added an item written in red
New Features / Improvements
- Support D2C for Genetec Security Center SaaS.
- Added [Detailed setting] to [HTTP alarm notification] settings.[More details(*1)>>]
- Added [Mic input] and [Audio output] buttons to the top of the live image page.
- Improved ONVIF connection.
- Enhanced security for handling incoming CGI commands.
For details, refer to Security Advisories | i-PRO Products page.
*If you are using the [Image quality setting] - [Batch change to the appropriate setting] for AI-VMD, please upgrade AI-VMD to V3.80 (or later).
*1 Detailed setting for HTTP alarm notification
Added "Detailed setting" to the settings for [HTTP alarm notification].
|
|
Resolved Issues
- Corrected issues where authentication using EAP-PEAP (IEEE 802.1X) failed depending on the network environment. 🅲
- Corrected an issue where SD recording for Remote Monitoring did not start, even when Remote Monitoring function was enabled with [Set recommended values] selected. 🅱
- Corrected an issue where the focus occasionally became blurred due to static electricity or other environmental factors. 🅲
Version 2.80
Release date: January 30, 2025
New Features / Improvements
- Support PKCS#12 for HTTPS.
- Added Host name setting to [Network settings].
- Added a link of [Detailed setting] to the screen for tablet terminals.
- Support “+” symbol in [Remote Monitoring registration mail address].
- Improved the connectivity to Video Management Software (VMS).
- Improved ONVIF connection.
- Optimize memory usage when using AI-VMD.
Resolved Issues
Corrected the following issues including other minor issue:
- Corrected an issue where image streaming to a specific 3rd party media player might stop. 🅲
- Improved the user interface. 🅲
- Corrected an issue where the Command alarm pop-up did not appear on the live window when [Alarm test] is executed. 🅲
Occurrence condition: When Command alarm is turned off. - Corrected an issue where HTTPS connection might not be possible after re-installing a CA certificate. 🅲
- Corrected an issue where the setting window did not open showing a blue screen instead. 🅲
Applies to: VMD area/ SCD area/ Audio detection/ Impact detection/ Casing open detection windows
Occurrence condition: When the web browser is closed while displaying the setting window