AI Processing Relay
Last updated: December 2025
Scenario:
With AI Processing Relay, a Non-AI camera can function as an AI camera. To use AI Processing Relay, an AI X-Series camera or an i-PRO mini camera is required. This guideline describes how to use AI Processing Relay to analyze video from a Non-AI camera with an AI application and send alarms to Genetec Security Center via i-PRO Active Guard:
1. Preparation
1.1 Installing i-PRO Active Guard
1.2 Installing AI Processing Relay
1.3. Camera Settings
2. Genetec Settings
3. i-PRO Active Guard Settings
4. Confirmation of Alarm Reception
About AI Processing Relay:
With AI Processing Relay, a Non-AI network camera can function as an AI camera.
For details, please refer to the following page.
AI Processing Relay
1. Preparation
1.1 Installing i-PRO Active Guard
1. Install i-PRO Active Guard. For details, refer to this page.
1.2 Installing AI Processing Relay
1. Install AI Processing Relay on an AI X-Series camera or an i-PRO mini camera.
For details, refer to the AI Processing Relay manual:
- AI X-Series camera - Section2: Preparation
- i-PRO mini camera - Section2: Preparation
1.3 Camera Settings
1. Configure the AI Processing Relay.
For details, refer to the AI Processing Relay manual:
- AI X-Series camera - Section3: Basic settings
- i-PRO mini camera - Section3: Basic settings
2. The AI Processing Relay sends two alarms via i-PRO Active Guard and TCP alarm notification for each detection. To prevent duplicate alarm notifications, send the following CGI command to the AI X-Series camera:
https://[AI X-Series Camera IP Address]/cgi-bin/setdata?AIENCTCPALM_CH234=1
When sending CGI commands, direct input of CGI commands in the browser URL is not allowed. Commands must be sent via iCT. Refer to the AI Processing Relay manual:
AI X-Series camera - Section3.4.1: Configure Camera Settings for Alarm Notification
2. Genetec Settings
2.1 Registering Non-AI Cameras
1. Register Non-AI cameras in Security Center.
2.2 Creating Alarms
1. Open [Config Tool], and click [Alarms].
2. Click [Add an entity] > [Alarm].
3. Enter the event name in the [Name] field. Refer to the table below for the event name.
In the following examples, AI-VMD Intruder (Genetec: Object detection in field) is configured.
| Event name | Event details |
|---|---|
| Registered Face Detection(i-PRO) | Notify when a face registered in the watchlist is detected. |
| Registered People Detection(i-PRO) | Notify when people registered in the watchlist is detected. |
| Registered Vehicle Detection(i-PRO) | Notify when a vehicle registered in the watchlist is detected. |
| Object detected in field(i-PRO) | Notify when an object detected in fields is detected.(*1) |
| Loitering(i-PRO) | Notify when an object loitering is detected.(*1) |
| Direction alarm(i-PRO) | Notify when a direction alarm of object is detected.(*1) |
| Object crossed line(i-PRO) | Notify when an Object crossed line is detected.(*1) |
| AI Scene Change Detection(i-PRO) | Notify when Scene Change Detection.(*1) |
| People counting alarm(i-PRO) | Notify when people counting alarm is detected.(*1) |
| License plate Detection(i-PRO) | Notify when a License plate is detected.(*2) |
| Registered License plate Detection(i-PRO) | Notify when a License plate registered in the watchlist is detected. |
| Unregistered License plate Detection(i-PRO) | Notify when a License plate unregistered in the watchlist is detected. |
| Registered Advanced Vehicle Detection(i-PRO) | Notify when a License plate registered in the watchlist set in appearance only is detected. |
| Code Detection(i-PRO) | Notify when an OCR code is detected.(*2) |
| Registered Code Detection(i-PRO) | Notify when an OCR code registered in the watchlist is detected. |
| Unregistered Code Detection(i-PRO) | Notify when an OCR code unregistered in the watchlist is detected. |
| Container Detection(i-PRO) | Notify when a Container code is detected.(*2) |
| Registered Container Detection(i-PRO) | Notify when a Container code registered in the watchlist is detected. |
| Unregistered Container Detection(i-PRO) | Notify when a Container code unregistered in the watchlist is detected. |
| Registered Advanced Container Detection(i-PRO) | Notify when a Container code registered in the watchlist set in [details] is detected. |
| The name set for [Event name] in C:\MultiAI\Backup\3rdPartyApp.config. | Notify events detected by Extension app. |
| MultiAI System Alarm(i-PRO) | Notify when system errors or events occur.(*3) |
These options should be enabled in section 3 (i-PRO Active Guard Settings).
*1:It is necessary to enable [Alarm of AI Processing relay app].
*2:It is necessary to enable [Notify all detected object].
*3:It is necessary to enable [System error], [Exceed the receive data limit (data loss)] and [Reach the max usage of image storage drive(delete old images)].
4. Click [Properties].
Set the user in [Recipients] and the Non-AI camera in [Attached entities].
3. i-PRO Active Guard Settings
1. Open the i-PRO Active Guard Server settings in a browser at https://127.0.0.1:8092.
2. Click the [Add Cameras] icon, then select [Add devices] > [AI Processing Relay.]
3. Enter the AI camera's IP address, username, and password, then click [Check].
Once the camera is displayed, click [Save].
The model name will be displayed as [Non-AI Camera (AI Camera)].
A message will appear prompting you to restart the i-PRO Active Guard Server, but you do not need to restart it yet. Restart it only after completing all settings.
4. Select the VMS server settings icon. Click [Advance] for the target VMS.
5. Check [Alarm Notification] and close the window.
By enabling Alarm notification instead of Event-to-Action on Genetec config tool, event detail will be shown on Alarm Monitoring/Reporting task. Beforehand, users must configure create alarms and alarm reception settings with the Genetec Config Tool in the section 2-2.
However, be aware that using Event-to-Action on the Genetec Config Tool does not display detailed information.
By clicking the information icon, you can view the event name details.
6. Select the [Alarm of AI Processing relay app] checkbox, and click [Save].
Then, click [Restart] to restart the i-PRO Active Guard Server.
4. Confirmation of Alarm Reception
A message appears in the Alarm Monitor tab when an alarm is received. Detailed information will be shown in the Context.
Genetec Security Center 5.12 / Driver Pack 12.5