1. Ana Sayfa
  2. Partners
  3. Video Management System Partners
  4. Milestone
  5. Custom Event with Alarm integration

 Custom Event with Alarm integration

Last update: July, 2024

i-PRO Maximizer's Alarm integration expands the selection of i-PRO AI features available in XProtect.
i-PRO Maximizer supports custom events. By setting custom events, XProtect can receive additional alarms.

・SD card Alarm

Please see the following page for an overview of i-PRO Maximizer.
The installer and installation manual can be downloaded from [HOW TO INSTALL] on the following page.

i-PRO Maximizer (milestonesys.com)


1. Camera Setting
2. Setup in XProtect Management Client
3. Confirmation of alarm reception in XProtect Smart Client

<Camera Setting>

1. HTTP Alarm Notification 

  Open [Setup] - [Alarm] - [Notification] - [HTTP alarm notification] screen in the camera browser.
  Check [Diag]. (Camera V2.60 or later)

HTTP Alarm Diag

 

<Setup in XProtect Management Client>

1.  Send HTTP alarm notification settings to the camera.
[Rules and Event] - [i-PRO Extended Actions] 
Click the [Update alarm sending on all cameras] button. By doing this, HTTP alarm notification will be automatically set for the connected i-PRO camera.
A pop-up will appear with the updated information for all cameras, so click "OK".


The IP address and HTTP alarm port of Milestone are added to [Address 1] of the camera's HTTP alarm notification, and the parameter "%alarmsrc2" is added to the notification data.

 

2. Custom Event.

Click the [Cusmom Event Mapping].
Set the [ID] and [Tag] for event mapping. Any name is OK for Tag.(ex, SD card not detected, SD card removal,….)

SD card Event ID
SD card full 01
SD card not detected 02
SD card Capacity ** % 03
SD card write error A5 or 04
SD card read error A6
SD card delete error A6
SD card filesystem error A7
SD card other error A8

 

 

Custom Event Mapping

 
3. Create a rule.
[Rules and Events]  -  [Rules]
Right-click Rules and click "Add Rule"
 The [Manage Rule] screen will appear. Enter a [Name:] and select [Perform an action on <event>] in "Select the rule type you want to create".
Click [event] in [Edit the rule description].
The subsequent rule creation procedure is the same as AI-VMD. Please refer to Step 7 and later of AI-VMD <Alarm setup in  Xprotect Management Client>.

 

4. Click on  [i-PRO Maximizer] and click on  [i-PRO Maximizer Events].
Select the i-PRO Custom Event(i-PRO Maximizer Event)

Custom Event in Rule

5.  Create an alarm definition.
Alarms - Alarm Definitions
Right-click "Alarm Definitions" and click "Add New"After configuring the settings, save them with [Save] at the top left of the screen.
 Enable:Check the checkbox
 Triggering event:(1st row):"i-PRO Maximizer Events"
 Triggering event:(2nd row):Select the i-PRO Custom Event.
 Sources:"All Cameras" or "Select target camera"

Custom Event in Action

 

6. Add Tag and Type to the Alarm Manager alarm list.
[Alarms] - [Alarm Data settings] - [Alarm List Configuration] 
Add "Tag" and "Type".

 

<Confirmation of alarm reception in XProtect Smart Client>

1. Start the SmartClient.
The status of received alarms can be checked in the [Alarm Manager] tab. If the "Tag" and "Type" added in step 5 are not displayed, they need to be added. Right-click on the title bar of the alarm list and add "Tag" and "Type".

 

2. When an alarm is received, the type of alarm is displayed in Tag and i-PRO Maxmizer is displayed in Type.

SD card alarm log

 

Milestone XProtect Management Client 2023 R3 /DP 13.0a
i-PRO Maximizer 1.0.1